{"title":"Hybrid Heating Panasonic","description":null,"products":[{"product_id":"panasonic-cu-hm18bahu-interios-1-5-ton-cold-climate-outdoor-heat-pump","title":"Panasonic CU-HM18BAHU INTERIOS 1.5 Ton Cold Climate Outdoor Heat Pump","description":"\u003cp\u003eThe Panasonic CU-HM18BAHU is a 1.5-ton cold-climate outdoor heat pump designed for Panasonic INTERIOS central heat pump and hybrid heating systems. It can be paired with the CS-HM24BAAU1 or CS-HM24BAAU2 A-coil for hybrid heating and cooling applications, integrating with a new or existing furnace for whole-home comfort. The system uses R454B refrigerant and is designed for cold-climate heating operation down to -20°F (-30°C).\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1.5 Ton Capacity:\u003c\/strong\u003e Provides 18,000 BTU\/h rated cooling capacity and 19,000 BTU\/h rated heating capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heating:\u003c\/strong\u003e Designed for heating operation down to -20°F (-30°C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e18,000 BTU Heating at 5°F:\u003c\/strong\u003e Delivers 18,000 BTU\/h at 5°F with a COP of 2.06.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR454B Refrigerant:\u003c\/strong\u003e Uses R454B refrigerant for the INTERIOS cold-climate heat pump system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter Heat Pump Condenser:\u003c\/strong\u003e Variable-capacity operation helps provide efficient heating and cooling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR Cold Climate Certified:\u003c\/strong\u003e Part of Panasonic's ENERGY STAR Cold Climate certified INTERIOS system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHybrid Heating Compatible:\u003c\/strong\u003e Designed to integrate with an existing or new furnace when paired with a compatible INTERIOS A-coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtreme Cold Operation:\u003c\/strong\u003e Provides a standard heating operating range down to -22°F (-30°C) in the submittal specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Outdoor sound level is approximately 58-59 dBA according to Panasonic's technical documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Base Pan:\u003c\/strong\u003e Supports cold-weather operation and helps manage condensate during low-temperature heating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CU-HM18BAHU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Outdoor Heat Pump Condenser\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Panasonic INTERIOS Extreme Heat Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity Class:\u003c\/strong\u003e 1.5 Ton\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Cooling Capacity:\u003c\/strong\u003e 18,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Capacity Range:\u003c\/strong\u003e 5,600-22,800 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Heating Capacity at 47°F:\u003c\/strong\u003e 19,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity Range at 47°F:\u003c\/strong\u003e 5,600-22,800 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity at 17°F:\u003c\/strong\u003e 15,200 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity at 5°F:\u003c\/strong\u003e 18,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOP at 5°F:\u003c\/strong\u003e 2.06\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Removal:\u003c\/strong\u003e 2.05 L\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2:\u003c\/strong\u003e 16.1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEER2:\u003c\/strong\u003e 11.7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSPF2 Region IV:\u003c\/strong\u003e 9.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSPF2 Region V:\u003c\/strong\u003e 7.8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R454B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant Oil:\u003c\/strong\u003e VG74\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant Oil Charge:\u003c\/strong\u003e 620 mL\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Power Supply:\u003c\/strong\u003e 208\/230V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Minimum Circuit Ampacity:\u003c\/strong\u003e 16 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Overcurrent Protection:\u003c\/strong\u003e 20 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Rated Load Amps:\u003c\/strong\u003e 10.5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Fan Motor Rated Load Amps:\u003c\/strong\u003e 0.9 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor Power Supply for Compatible System:\u003c\/strong\u003e 24V, 60Hz, Single Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Wiring:\u003c\/strong\u003e AWG 20-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling System Power Input:\u003c\/strong\u003e 1,538 W rated; 530-2,120 W range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating System Power Input:\u003c\/strong\u003e 1,687 W rated; 350-2,040 W range\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompressor \u0026amp; Outdoor Unit\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Type:\u003c\/strong\u003e Rotary\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Model:\u003c\/strong\u003e KTM240D46UKT2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Airflow:\u003c\/strong\u003e 1,766 CFM maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Noise Level:\u003c\/strong\u003e 58 dBA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Fan Motor:\u003c\/strong\u003e DC motor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Exchanger:\u003c\/strong\u003e Outdoor coil designed for cold-climate heat pump operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOperating Conditions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Outdoor Operating Range:\u003c\/strong\u003e -22°F to 122°F (-30°C to 50°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Outdoor Operating Range:\u003c\/strong\u003e -22°F to 75°F (-30°C to 24°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heating:\u003c\/strong\u003e Down to -20°F (-30°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating at 5°F:\u003c\/strong\u003e 18,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating COP at 5°F:\u003c\/strong\u003e 2.06\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePiping Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant Control:\u003c\/strong\u003e Electronic Expansion Valve (EXV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid Pipe Size:\u003c\/strong\u003e 3\/8 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Pipe Size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Piping Length:\u003c\/strong\u003e 98 ft (30 m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Height Difference:\u003c\/strong\u003e 66 ft (20 m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Pre-Charged Piping Length:\u003c\/strong\u003e 24.6 ft (7.5 m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Refrigerant Charge:\u003c\/strong\u003e 74.08 oz (2.1 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Refrigerant Charge:\u003c\/strong\u003e 0.7 oz\/ft (65 g\/m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Method:\u003c\/strong\u003e Flared\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eDimensions \u0026amp; Weight\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit Dimensions:\u003c\/strong\u003e 35.04 x 13.46 x 26.50 in (W x D x H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit Dimensions:\u003c\/strong\u003e 890 x 342 x 673 mm (W x D x H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit Weight:\u003c\/strong\u003e 101.4 lb (46 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Dimensions:\u003c\/strong\u003e 39.17 x 15.67 x 29.13 in (W x D x H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGross Shipping Weight:\u003c\/strong\u003e 109.13 lb (49.5 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Dimensions:\u003c\/strong\u003e 995 x 398 x 740 mm (W x D x H)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompatible Indoor A-Coils\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCS-HM24BAAU1\u003c\/li\u003e\n\u003cli\u003eCS-HM24BAAU2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSystem Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type:\u003c\/strong\u003e Central ducted heat pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Hybrid heating and cooling \/ dual-fuel system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor Configuration:\u003c\/strong\u003e A-coil integrated with a new or existing furnace\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible System:\u003c\/strong\u003e Panasonic INTERIOS 1.5 Ton Hybrid Heat Pump System\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R454B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e ENERGY STAR Cold Climate\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e CU-HM18BAHU is an outdoor heat pump unit and must be paired with a compatible Panasonic indoor A-coil. Panasonic lists CS-HM24BAAU1 and CS-HM24BAAU2 as compatible A-coils for the 18K configuration. Always verify the complete system combination, piping requirements, electrical requirements, and installation conditions before installation.\u003c\/p\u003e","brand":"Panasonic Products","offers":[{"title":"Default Title","offer_id":44875447435444,"sku":"kpi261-CU-HM18BAHU","price":2901.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0645\/8484\/3444\/files\/CS-HM24BAAU2_2761b445-a538-48ab-9419-b88f500c4ff9.png?v=1789910704"},{"product_id":"panasonic-cu-hm24bahu-interios-2-ton-cold-climate-outdoor-heat-pump","title":"Panasonic CU-HM24BAHU INTERIOS 2 Ton Cold Climate Outdoor Heat Pump","description":"\u003cp\u003eThe Panasonic CU-HM24BAHU is a 2-ton cold-climate outdoor heat pump condenser designed for the INTERIOS hybrid heating and cooling system. When paired with a compatible CS-HM24BAAU1 or CS-HM24BAAU2 A-coil, it integrates with a new or existing furnace to provide whole-home heating and cooling. The system uses R454B refrigerant, inverter-driven heat pump technology, and is designed for cold-climate operation down to -20°F (-30°C).\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 Ton Capacity:\u003c\/strong\u003e Provides 24,000 BTU\/h rated cooling capacity and 25,000 BTU\/h rated heating capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heating:\u003c\/strong\u003e Designed for heating operation down to -20°F (-30°C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21,000 BTU at 5°F:\u003c\/strong\u003e Delivers 21,000 BTU\/h heating capacity at 5°F with a COP of 1.8.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR454B Refrigerant:\u003c\/strong\u003e Uses R454B refrigerant for the INTERIOS cold-climate heat pump system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter Heat Pump Condenser:\u003c\/strong\u003e Variable-capacity inverter operation helps provide efficient heating and cooling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHybrid Heating Compatible:\u003c\/strong\u003e Designed to integrate with a new or existing furnace through a compatible A-coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR Cold Climate Certified:\u003c\/strong\u003e The CU-HM24BAHU system is ENERGY STAR certified for cold-climate applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Position System:\u003c\/strong\u003e Compatible with Panasonic INTERIOS A-coil configurations for flexible installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Outdoor Operation:\u003c\/strong\u003e Outdoor sound level is approximately 60 dBA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR454B System:\u003c\/strong\u003e Uses a lower-impact A2L refrigerant with zero ozone depletion potential.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CU-HM24BAHU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Outdoor Heat Pump Condenser\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Panasonic INTERIOS Extreme Heat Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity Class:\u003c\/strong\u003e 2 Ton\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Cooling Capacity:\u003c\/strong\u003e 24,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Capacity Range:\u003c\/strong\u003e 7,900-27,600 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Heating Capacity:\u003c\/strong\u003e 25,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity Range:\u003c\/strong\u003e 6,500-30,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity at 17°F:\u003c\/strong\u003e 21,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity at 5°F:\u003c\/strong\u003e 21,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOP at 5°F:\u003c\/strong\u003e 1.8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2:\u003c\/strong\u003e 16.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEER2:\u003c\/strong\u003e 10.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSPF2 Region IV:\u003c\/strong\u003e 9.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSPF2 Region V:\u003c\/strong\u003e 7.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOP:\u003c\/strong\u003e 3.20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R454B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant Charge:\u003c\/strong\u003e 74.08 oz (2.1 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePerformance \u0026amp; Power Input\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Capacity - Minimum:\u003c\/strong\u003e 7,900 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Capacity - Rated:\u003c\/strong\u003e 24,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Capacity - Maximum:\u003c\/strong\u003e 27,600 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Power Input - Minimum:\u003c\/strong\u003e 680 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Power Input - Rated:\u003c\/strong\u003e 2,400 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Power Input - Maximum:\u003c\/strong\u003e 2,890 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity - Minimum:\u003c\/strong\u003e 6,500 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity - Rated:\u003c\/strong\u003e 25,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity - Maximum:\u003c\/strong\u003e 30,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Power Input - Minimum:\u003c\/strong\u003e 330 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Power Input - Rated:\u003c\/strong\u003e 2,290 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Power Input - Maximum:\u003c\/strong\u003e 2,900 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Power Supply:\u003c\/strong\u003e 208\/230V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Circuit Ampacity:\u003c\/strong\u003e 19 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Fuse \/ Overcurrent Protection:\u003c\/strong\u003e 20 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Fan Motor RLA:\u003c\/strong\u003e 1.0 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor Power Supply:\u003c\/strong\u003e 24V, Single Phase, 60Hz through compatible A-coil\/system\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompressor \u0026amp; Outdoor Unit\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Type:\u003c\/strong\u003e Rotary inverter compressor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Airflow:\u003c\/strong\u003e 1,766 CFM maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Noise Level:\u003c\/strong\u003e 60 dBA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R454B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant Oil:\u003c\/strong\u003e VG75\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type:\u003c\/strong\u003e Inverter-driven cold-climate heat pump\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOperating Conditions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Outdoor Operating Range:\u003c\/strong\u003e -22°F to 122°F (-30°C to 50°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Outdoor Operating Range:\u003c\/strong\u003e -22°F to 75°F (-30°C to 24°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heating:\u003c\/strong\u003e Down to -20°F (-30°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating at 5°F:\u003c\/strong\u003e 21,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOP at 5°F:\u003c\/strong\u003e 1.8\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePiping Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant Control:\u003c\/strong\u003e Electronic Expansion Valve (EXV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid Pipe Size:\u003c\/strong\u003e 3\/8 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Pipe Size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Piping Length:\u003c\/strong\u003e 164 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Indoor\/Outdoor Height Difference:\u003c\/strong\u003e 82 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Refrigerant:\u003c\/strong\u003e 0.7 oz\/ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Method:\u003c\/strong\u003e Flared\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eDimensions \u0026amp; Weight\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit Dimensions:\u003c\/strong\u003e 26-1\/2 x 35 x 13-1\/2 in (H x W x D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit Dimensions:\u003c\/strong\u003e Approximately 673 x 890 x 342 mm (H x W x D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit Weight:\u003c\/strong\u003e 102 lb (46 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Carton Dimensions:\u003c\/strong\u003e 29-1\/4 x 39-1\/4 x 15-3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Carton Weight:\u003c\/strong\u003e 109 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompatible Indoor A-Coils\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCS-HM24BAAU1\u003c\/li\u003e\n\u003cli\u003eCS-HM24BAAU2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSystem Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type:\u003c\/strong\u003e Central ducted heat pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Hybrid heating and cooling \/ dual-fuel system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor Configuration:\u003c\/strong\u003e A-coil integrated with a new or existing furnace\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Capacity:\u003c\/strong\u003e 2 Ton\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R454B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e ENERGY STAR Cold Climate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Operation:\u003c\/strong\u003e Down to -20°F (-30°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e CU-HM24BAHU is an outdoor condenser and must be paired with a compatible Panasonic INTERIOS A-coil. Panasonic lists CS-HM24BAAU1 and CS-HM24BAAU2 as compatible indoor A-coils. Verify the complete system combination, piping requirements, electrical requirements, and installation conditions before installation.\u003c\/p\u003e","brand":"Panasonic Products","offers":[{"title":"Default Title","offer_id":44875447468212,"sku":"kpi261-CU-HM24BAHU","price":3480.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0645\/8484\/3444\/files\/CS-HM24BAAU2.png?v=1789910704"},{"product_id":"panasonic-cu-hm30bahu-interios-2-5-ton-cold-climate-outdoor-heat-pump","title":"Panasonic CU-HM30BAHU INTERIOS 2.5 Ton Cold Climate Outdoor Heat Pump","description":"\u003cp\u003eThe Panasonic CU-HM30BAHU is a 2.5-ton cold-climate outdoor heat pump condenser designed for the INTERIOS hybrid heating and cooling system. It pairs with compatible CS-HM36BAAU1, CS-HM36BAAU2, or CS-HM36BAAU3 A-coils and can integrate with a new or existing furnace to provide whole-home heating and cooling. The system uses R454B refrigerant, inverter-driven heat pump technology, and is designed for cold-climate operation down to -20°F (-30°C).\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.5 Ton Capacity:\u003c\/strong\u003e Provides 30,000 BTU\/h rated cooling capacity and 30,000 BTU\/h rated heating capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heating:\u003c\/strong\u003e Designed for continuous heating operation down to -20°F (-30°C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30,400 BTU\/h at 5°F:\u003c\/strong\u003e Delivers 30,400 BTU\/h at 5°F with a COP of 1.8.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR454B Refrigerant:\u003c\/strong\u003e Uses R454B refrigerant with zero ozone depletion potential.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter Heat Pump Condenser:\u003c\/strong\u003e Variable-capacity operation provides efficient heating and cooling performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHybrid Heating Compatible:\u003c\/strong\u003e Designed to integrate with a new or existing furnace through a compatible A-coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR Cold Climate Certified:\u003c\/strong\u003e The compatible INTERIOS hybrid system is ENERGY STAR certified for cold-climate applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Position A-Coil Compatibility:\u003c\/strong\u003e Compatible with Panasonic CS-HM36BAAU1, CS-HM36BAAU2, and CS-HM36BAAU3 A-coils.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA2L Refrigerant System:\u003c\/strong\u003e Includes compatibility with Panasonic's R454B refrigerant safety system and A2L sensor-equipped indoor units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Base Pan:\u003c\/strong\u003e Designed to support reliable operation in extreme cold conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Outdoor sound level is rated at approximately 64 dBA in the hybrid A-coil system documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CU-HM30BAHU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Outdoor Heat Pump Condenser\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Panasonic INTERIOS Extreme Heat Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity Class:\u003c\/strong\u003e 2.5 Ton\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Cooling Capacity:\u003c\/strong\u003e 30,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Capacity Range:\u003c\/strong\u003e 12,600-34,800 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Heating Capacity at 47°F:\u003c\/strong\u003e 30,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity Range at 47°F:\u003c\/strong\u003e 9,800-35,900 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity at 17°F:\u003c\/strong\u003e 30,400 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity at 5°F:\u003c\/strong\u003e 30,400 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOP at 5°F:\u003c\/strong\u003e 1.8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2:\u003c\/strong\u003e 15.3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEER2:\u003c\/strong\u003e 10.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSPF2 Region IV:\u003c\/strong\u003e 9.3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSPF2 Region V:\u003c\/strong\u003e 7.7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOP:\u003c\/strong\u003e 3.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R454B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Refrigerant Charge:\u003c\/strong\u003e 105.82 oz (3.0 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePerformance \u0026amp; Power Input\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Capacity - Minimum:\u003c\/strong\u003e 12,600 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Capacity - Rated:\u003c\/strong\u003e 30,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Capacity - Maximum:\u003c\/strong\u003e 34,800 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Power Input - Minimum:\u003c\/strong\u003e 1,160 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Power Input - Rated:\u003c\/strong\u003e 3,000 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Power Input - Maximum:\u003c\/strong\u003e 3,680 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity - Minimum:\u003c\/strong\u003e 9,800 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity - Rated:\u003c\/strong\u003e 30,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity - Maximum:\u003c\/strong\u003e 35,900 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Power Input - Minimum:\u003c\/strong\u003e 710 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Power Input - Rated:\u003c\/strong\u003e 2,931 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Power Input - Maximum:\u003c\/strong\u003e 3,590 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Power Supply:\u003c\/strong\u003e 208\/230V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Circuit Ampacity:\u003c\/strong\u003e 29.5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Overcurrent Protection:\u003c\/strong\u003e 30 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Rated Load Amps:\u003c\/strong\u003e 22.4 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Fan Motor Rated Load Amps:\u003c\/strong\u003e 1.5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor Power Supply:\u003c\/strong\u003e 24V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Wiring:\u003c\/strong\u003e AWG 20-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompressor \u0026amp; Outdoor Unit\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Type:\u003c\/strong\u003e Rotary\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Model:\u003c\/strong\u003e MTH356UKRC8FQL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Airflow:\u003c\/strong\u003e 3,002 CFM maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Noise Level:\u003c\/strong\u003e 64 dBA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Fan Motor:\u003c\/strong\u003e DC motor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant Control:\u003c\/strong\u003e Electronic Expansion Valve (EXV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R454B\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOperating Conditions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Outdoor Operating Range:\u003c\/strong\u003e -22°F to 122°F (-30°C to 50°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Outdoor Operating Range:\u003c\/strong\u003e -22°F to 75°F (-30°C to 24°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heating:\u003c\/strong\u003e Down to -20°F (-30°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating at 17°F:\u003c\/strong\u003e 30,400 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating at 5°F:\u003c\/strong\u003e 30,400 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOP at 5°F:\u003c\/strong\u003e 1.8\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePiping Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Method:\u003c\/strong\u003e Flared\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant Control:\u003c\/strong\u003e Electronic Expansion Valve (EXV)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid Pipe Size:\u003c\/strong\u003e 3\/8 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Pipe Size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Piping Length:\u003c\/strong\u003e 164 ft (50 m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Indoor\/Outdoor Height Difference:\u003c\/strong\u003e 82 ft (25 m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Pre-Charged Piping Length:\u003c\/strong\u003e 24.6 ft (7.5 m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Refrigerant Charge:\u003c\/strong\u003e 0.7 oz\/ft (65 g\/m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eDimensions \u0026amp; Weight\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit Dimensions:\u003c\/strong\u003e 31-7\/8 x 37-1\/4 x 16-1\/8 in (H x W x D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit Dimensions:\u003c\/strong\u003e 810 x 946 x 410 mm (H x W x D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit Net Weight:\u003c\/strong\u003e 164.02 lb (74.4 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit Gross Weight:\u003c\/strong\u003e 174.6 lb (79.2 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Package Dimensions:\u003c\/strong\u003e 42.91 x 19.69 x 34.84 in (W x D x H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Package Dimensions:\u003c\/strong\u003e 1090 x 500 x 885 mm (W x D x H)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompatible Indoor A-Coils\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCS-HM36BAAU1\u003c\/li\u003e\n\u003cli\u003eCS-HM36BAAU2\u003c\/li\u003e\n\u003cli\u003eCS-HM36BAAU3\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSystem Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type:\u003c\/strong\u003e Central ducted heat pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Hybrid heating and cooling \/ dual-fuel system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor Configuration:\u003c\/strong\u003e A-coil integrated with a new or existing furnace\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Capacity:\u003c\/strong\u003e 2.5 Ton\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R454B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e ENERGY STAR Cold Climate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Operation:\u003c\/strong\u003e Down to -20°F (-30°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e CU-HM30BAHU is an outdoor condenser and must be paired with a compatible Panasonic INTERIOS A-coil. Panasonic lists CS-HM36BAAU1, CS-HM36BAAU2, and CS-HM36BAAU3 as compatible A-coils for the 30K configuration. Verify the complete system combination, piping requirements, electrical requirements, and installation conditions before installation.\u003c\/p\u003e","brand":"Panasonic Products","offers":[{"title":"Default Title","offer_id":44875447500980,"sku":"kpi261-CU-HM30BAHU","price":4730.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0645\/8484\/3444\/files\/CS-HM36BAAU2_34bf478c-ff1c-402b-ab37-d780db40a037.png?v=1789910704"},{"product_id":"panasonic-cu-hm36bahu-interios-3-ton-outdoor-heat-pump","title":"Panasonic CU-HM36BAHU INTERIOS 3 Ton Outdoor Heat Pump","description":"\u003cp\u003eThe Panasonic INTERIOS CU-HM36BAHU is a 3-ton outdoor extreme heat pump designed for hybrid heating and cooling applications with compatible INTERIOS A-coil indoor units. It integrates with a new or existing furnace to provide whole-home heating and cooling while supporting cold-climate operation down to -22°F (-30°C). The system uses R454B refrigerant and is ENERGY STAR Cold Climate certified.\u003c\/p\u003e\n\n\u003cp\u003eThe CU-HM36BAHU delivers 36,000 BTU\/h of rated cooling capacity and 38,000 BTU\/h of rated heating capacity at 47°F. At 17°F, the rated heating capacity is 29,200 BTU\/h, while at 5°F the system provides 36,000 BTU\/h with a COP of 1.9. The outdoor unit uses a rotary compressor, electronic expansion valve, and supports flexible installation and hybrid dual-fuel operation.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e3-ton class outdoor heat pump for INTERIOS hybrid heating and cooling systems\u003c\/li\u003e\n\u003cli\u003e36,000 BTU\/h rated cooling capacity\u003c\/li\u003e\n\u003cli\u003e38,000 BTU\/h rated heating capacity at 47°F\u003c\/li\u003e\n\u003cli\u003e36,000 BTU\/h rated heating capacity at 5°F\u003c\/li\u003e\n\u003cli\u003e29,200 BTU\/h rated heating capacity at 17°F\u003c\/li\u003e\n\u003cli\u003eCold-climate operation down to -22°F (-30°C)\u003c\/li\u003e\n\u003cli\u003eR454B refrigerant with lower global warming potential than R410A\u003c\/li\u003e\n\u003cli\u003eENERGY STAR Cold Climate certified system\u003c\/li\u003e\n\u003cli\u003eRotary compressor with electronic expansion valve control\u003c\/li\u003e\n\u003cli\u003eBuilt-in A2L refrigerant sensor system\u003c\/li\u003e\n\u003cli\u003eBuilt-in base pan for extreme cold-weather heating operation\u003c\/li\u003e\n\u003cli\u003eDesigned for hybrid dual-fuel applications with compatible A-coil indoor units\u003c\/li\u003e\n\u003cli\u003eMaximum piping length up to 246 ft\u003c\/li\u003e\n\u003cli\u003eMaximum indoor-to-outdoor height difference of 98 ft\u003c\/li\u003e\n\u003cli\u003eOutdoor airflow up to 3,002 CFM\u003c\/li\u003e\n\u003cli\u003eOutdoor noise level of 64 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePerformance Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit:\u003c\/strong\u003e CU-HM36BAHU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type:\u003c\/strong\u003e Hybrid A-Coil Heat Pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Capacity:\u003c\/strong\u003e 3 Ton\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Cooling Capacity:\u003c\/strong\u003e 36,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Capacity Range:\u003c\/strong\u003e 12,100–41,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Heating Capacity at 47°F:\u003c\/strong\u003e 38,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity Range at 47°F:\u003c\/strong\u003e 11,500–46,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Heating Capacity at 17°F:\u003c\/strong\u003e 29,200 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Heating Capacity at 5°F:\u003c\/strong\u003e 36,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Heating Capacity at 5°F:\u003c\/strong\u003e 36,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Removal:\u003c\/strong\u003e 4.91 L\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2:\u003c\/strong\u003e 15.8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEER2:\u003c\/strong\u003e 10.7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSPF2 Region IV:\u003c\/strong\u003e 9.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOP:\u003c\/strong\u003e 3.3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOP at 5°F:\u003c\/strong\u003e 1.9\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePower \u0026amp; Electrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Power Supply:\u003c\/strong\u003e 208\/230V, 1 Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor Power Supply:\u003c\/strong\u003e 24V, 1 Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling System Power Input:\u003c\/strong\u003e 3,364 W rated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Power Input Range:\u003c\/strong\u003e 1,020–4,520 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating System Power Input:\u003c\/strong\u003e 3,375 W rated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Power Input Range:\u003c\/strong\u003e 800–4,540 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor MCA:\u003c\/strong\u003e 29 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor MOP:\u003c\/strong\u003e 30 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor RLA:\u003c\/strong\u003e 20.5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Fan Motor RLA:\u003c\/strong\u003e 2.4 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Wiring:\u003c\/strong\u003e AWG 20-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompressor \u0026amp; Refrigeration\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Type:\u003c\/strong\u003e Rotary\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Model:\u003c\/strong\u003e EKPQ420D1UMUA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R454B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Refrigerant Charge:\u003c\/strong\u003e 126.99 oz \/ 3.6 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Refrigerant:\u003c\/strong\u003e 0.7 oz\/ft \/ 65 g\/m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant Oil:\u003c\/strong\u003e VG75\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant Oil Charge:\u003c\/strong\u003e 1,460 mL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThrottle Type:\u003c\/strong\u003e Electronic Expansion Valve (EXV)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePiping Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Method:\u003c\/strong\u003e Flared\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid Pipe Size:\u003c\/strong\u003e 3\/8 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Pipe Size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Piping Length:\u003c\/strong\u003e 246 ft \/ 75 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Height Difference:\u003c\/strong\u003e 98 ft \/ 30 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Pre-Charged Piping Length:\u003c\/strong\u003e 24.6 ft \/ 7.5 m\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOperating Conditions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Operating Range:\u003c\/strong\u003e -22°F to 122°F (-30°C to 50°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Operating Range:\u003c\/strong\u003e -22°F to 75°F (-30°C to 24°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heating Operation:\u003c\/strong\u003e Down to -22°F (-30°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOutdoor Unit Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W × D × H):\u003c\/strong\u003e 38.58 × 16.34 × 38.39 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W × D × H):\u003c\/strong\u003e 980 × 415 × 975 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 204.15 lb \/ 92.6 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGross Weight:\u003c\/strong\u003e 235.23 lb \/ 106.7 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outdoor Airflow:\u003c\/strong\u003e 3,002 CFM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Noise Level:\u003c\/strong\u003e 64 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompatible Indoor Units\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCS-HM36BAAU1\u003c\/li\u003e\n\u003cli\u003eCS-HM36BAAU2\u003c\/li\u003e\n\u003cli\u003eCS-HM36BAAU3\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cp\u003eThe CU-HM36BAHU is designed for central ducted hybrid heating and cooling systems. When paired with a compatible INTERIOS A-coil, it can integrate with a furnace to provide dual-fuel whole-home heating and cooling. The system supports multi-position A-coil installation, R454B refrigerant, A2L refrigerant sensing, and extreme cold-climate operation.\u003c\/p\u003e","brand":"Panasonic Products","offers":[{"title":"Default Title","offer_id":44875447533748,"sku":"kpi261-CU-HM36BAHU","price":6451.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0645\/8484\/3444\/files\/CS-HM36BAAU2.png?v=1789910704"},{"product_id":"panasonic-cu-hm48bahu-interios-4-ton-outdoor-heat-pump","title":"Panasonic CU-HM48BAHU INTERIOS 4 Ton Outdoor Heat Pump","description":"\u003cp\u003eThe Panasonic INTERIOS CU-HM48BAHU is a 4-ton class outdoor extreme-heat heat pump designed for hybrid heating and cooling applications. It is engineered to work with compatible INTERIOS A-coil indoor units and a new or existing furnace to provide whole-home heating and cooling. The system uses R454B refrigerant and is designed for cold-climate operation down to -22°F (-30°C).\u003c\/p\u003e\n\n\u003cp\u003eWhen paired with the CS-HM60BAAU4 A-coil, the CU-HM48BAHU provides a rated cooling capacity of 45,000 BTU\/h and a rated heating capacity of 38,000 BTU\/h, with operation across a broad temperature range. The outdoor unit features electronic expansion valve control, a rotary compressor, built-in A2L refrigerant sensing, and a base pan designed to support extreme cold-weather operation.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e4-ton class outdoor heat pump for INTERIOS hybrid heating and cooling systems\u003c\/li\u003e\n\u003cli\u003eCompatible with the CS-HM60BAAU4 INTERIOS A-coil\u003c\/li\u003e\n\u003cli\u003e45,000 BTU\/h rated cooling capacity when paired with CS-HM60BAAU4\u003c\/li\u003e\n\u003cli\u003e38,000 BTU\/h rated heating capacity when paired with CS-HM60BAAU4\u003c\/li\u003e\n\u003cli\u003eHeating capacity of up to 46,000 BTU\/h at maximum operating conditions\u003c\/li\u003e\n\u003cli\u003eCold-climate heating operation down to -22°F (-30°C)\u003c\/li\u003e\n\u003cli\u003eR454B refrigerant\u003c\/li\u003e\n\u003cli\u003eENERGY STAR Cold Climate system platform\u003c\/li\u003e\n\u003cli\u003eRotary compressor\u003c\/li\u003e\n\u003cli\u003eElectronic expansion valve for refrigerant control\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant sensor included\u003c\/li\u003e\n\u003cli\u003eBuilt-in base pan for cold-weather operation\u003c\/li\u003e\n\u003cli\u003eMulti-position hybrid A-coil system compatibility\u003c\/li\u003e\n\u003cli\u003eMaximum piping length up to 246 ft\u003c\/li\u003e\n\u003cli\u003eMaximum indoor-to-outdoor height difference of 98 ft\u003c\/li\u003e\n\u003cli\u003eOutdoor airflow up to 3,002 CFM\u003c\/li\u003e\n\u003cli\u003eOutdoor noise level of approximately 64 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePerformance Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CU-HM48BAHU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type:\u003c\/strong\u003e Hybrid A-Coil Extreme Heat Pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Capacity:\u003c\/strong\u003e 4 Ton Class\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible A-Coil:\u003c\/strong\u003e CS-HM60BAAU4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Capacity with CS-HM60BAAU4:\u003c\/strong\u003e 15,500–45,000–47,000 BTU\/h (Min\/Rated\/Max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity with CS-HM60BAAU4:\u003c\/strong\u003e 11,500–38,000–46,000 BTU\/h (Min\/Rated\/Max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2:\u003c\/strong\u003e 15.8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEER2:\u003c\/strong\u003e 10.7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSPF2 Region IV:\u003c\/strong\u003e 9.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSPF2 Region V:\u003c\/strong\u003e 7.9\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOP:\u003c\/strong\u003e 3.30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity at 5°F:\u003c\/strong\u003e 42,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOP at 5°F:\u003c\/strong\u003e Approximately 1.85\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R454B\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Power Supply:\u003c\/strong\u003e 208\/230V, 1 Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor\/A-Coil Power:\u003c\/strong\u003e 24V, 1 Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Input Power:\u003c\/strong\u003e 1,020–3,364–4,520 W (Min\/Rated\/Max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Input Power:\u003c\/strong\u003e 800–3,375–4,540 W (Min\/Rated\/Max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Circuit Ampacity:\u003c\/strong\u003e 29.0 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Fuse:\u003c\/strong\u003e 30 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Fan Motor RLA:\u003c\/strong\u003e 2.4 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eRefrigeration \u0026amp; Piping\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R454B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Refrigerant Charge:\u003c\/strong\u003e 126.99 oz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid Pipe:\u003c\/strong\u003e 3\/8 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Pipe:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Flared\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Piping Length:\u003c\/strong\u003e 246 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Height Difference:\u003c\/strong\u003e 98 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Pre-Charged Piping Length:\u003c\/strong\u003e 24.6 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Refrigerant:\u003c\/strong\u003e 0.7 oz\/ft\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOperating Conditions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Operating Range:\u003c\/strong\u003e -22°F to 122°F (-30°C to 50°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Operating Range:\u003c\/strong\u003e -22°F to 75°F (-30°C to 24°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Operation:\u003c\/strong\u003e Down to -22°F (-30°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOutdoor Unit Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit:\u003c\/strong\u003e CU-HM48BAHU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H × W × D):\u003c\/strong\u003e 38-3\/8 × 38-19\/32 × 16-5\/16 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H × W × D):\u003c\/strong\u003e Approximately 975 × 980 × 415 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit Net Weight:\u003c\/strong\u003e 204 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit Gross\/Carton Weight:\u003c\/strong\u003e 235 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Carton Dimensions:\u003c\/strong\u003e 42-5\/8 × 45-1\/8 × 19-3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Airflow:\u003c\/strong\u003e 3,002 CFM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Noise Level:\u003c\/strong\u003e 64 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompatible Indoor Units\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCS-HM60BAAU4\u003c\/li\u003e\n\u003cli\u003eCS-HM60BAMU3\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHybrid Heating Application\u003c\/h2\u003e\n\u003cp\u003eThe CU-HM48BAHU is designed for a central ducted hybrid dual-fuel configuration. The heat pump provides heating during cold conditions and cooling during warmer conditions, while the connected furnace can provide supplemental whole-home heating when outdoor temperatures reach extreme cold conditions. Panasonic's INTERIOS hybrid platform is designed for continuous operation down to -22°F (-30°C).\u003c\/p\u003e\n\n\u003ch2\u003eRefrigerant \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003eThe system uses R454B refrigerant and incorporates an A2L refrigerant sensor. Panasonic specifies R454B for the INTERIOS platform and identifies the A-coil system as a cold-climate hybrid heat pump solution with built-in features for installation and service.\u003c\/p\u003e","brand":"Panasonic Products","offers":[{"title":"Default Title","offer_id":44875447566516,"sku":"kpi261-CU-HM48BAHU","price":7333.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0645\/8484\/3444\/files\/CS-HM60BAAU4_59ce7dbf-2625-4651-aca3-b883de1c70b4.png?v=1789910704"},{"product_id":"panasonic-cu-hm55bahu-interios-4-5-ton-outdoor-heat-pump","title":"Panasonic CU-HM55BAHU INTERIOS 4.5 Ton Outdoor Heat Pump","description":"\u003cp\u003eThe Panasonic INTERIOS CU-HM55BAHU is a 4.5-ton-class outdoor extreme heat pump designed for central ducted heating and cooling applications. It is compatible with Panasonic INTERIOS A-coil systems for hybrid dual-fuel heating and cooling, allowing the heat pump to integrate with a new or existing furnace for whole-home comfort.\u003c\/p\u003e\n\n\u003cp\u003eThe CU-HM55BAHU uses R454B refrigerant and provides cold-climate heating operation down to -22°F (-30°C). When paired with the CS-HM60BAAU4 A-coil, the system provides up to 53,000 BTU\/h rated cooling capacity and 58,000 BTU\/h rated heating capacity. Panasonic specifies continuously variable compressor operation, electronic refrigerant control, and a built-in base pan for cold-climate operation.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e4.5-ton-class outdoor extreme heat pump\u003c\/li\u003e\n\u003cli\u003eDesigned for INTERIOS hybrid heating and cooling applications\u003c\/li\u003e\n\u003cli\u003eCompatible with CS-HM60BAAU4 and CS-HM60BAMU3 indoor A-coils\u003c\/li\u003e\n\u003cli\u003eUp to 53,000 BTU\/h rated cooling capacity with CS-HM60BAAU4\u003c\/li\u003e\n\u003cli\u003e58,000 BTU\/h rated heating capacity with CS-HM60BAAU4\u003c\/li\u003e\n\u003cli\u003eHeating capacity up to 52,000 BTU\/h at 5°F in the CS-HM60BAAU4 hybrid configuration\u003c\/li\u003e\n\u003cli\u003eCold-climate operation down to -22°F (-30°C)\u003c\/li\u003e\n\u003cli\u003eR454B refrigerant\u003c\/li\u003e\n\u003cli\u003eContinuously variable compressor operation\u003c\/li\u003e\n\u003cli\u003eTwin-rotary compressor\u003c\/li\u003e\n\u003cli\u003eElectronic expansion valve refrigerant control\u003c\/li\u003e\n\u003cli\u003eBuilt-in base pan for extreme cold-weather operation\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant sensor included with compatible A-coil system\u003c\/li\u003e\n\u003cli\u003eCentral ducted, whole-home heating and cooling design\u003c\/li\u003e\n\u003cli\u003eMaximum piping length of 246 ft\u003c\/li\u003e\n\u003cli\u003eMaximum height difference of approximately 98 ft\u003c\/li\u003e\n\u003cli\u003eOutdoor airflow up to 2,649 CFM\u003c\/li\u003e\n\u003cli\u003eOutdoor noise level of approximately 64 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePerformance Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CU-HM55BAHU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type:\u003c\/strong\u003e INTERIOS Extreme Heat Hybrid A-Coil Heat Pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Capacity Class:\u003c\/strong\u003e 4.5 Ton\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Cooling Capacity:\u003c\/strong\u003e 53,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Capacity Range:\u003c\/strong\u003e 17,600–53,400 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Heating Capacity:\u003c\/strong\u003e 58,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity Range:\u003c\/strong\u003e 21,200–59,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity at 5°F:\u003c\/strong\u003e 52,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOP at 5°F:\u003c\/strong\u003e Approximately 1.8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2:\u003c\/strong\u003e 15.2 with CS-HM60BAAU4 hybrid A-coil configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEER2:\u003c\/strong\u003e 10.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSPF2 Region IV:\u003c\/strong\u003e 8.1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSPF2 Region V:\u003c\/strong\u003e 6.8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R454B\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Power Supply:\u003c\/strong\u003e 208\/230V, 1 Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor\/A-Coil Power:\u003c\/strong\u003e 24V, 1 Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Input Power:\u003c\/strong\u003e 1,520–6,020–6,040 W (Min\/Rated\/Max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Input Power:\u003c\/strong\u003e 1,580–6,159–6,750 W (Min\/Rated\/Max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Fan Motor RLA:\u003c\/strong\u003e 1.2 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Circuit Ampacity:\u003c\/strong\u003e Refer to the applicable installation\/submittal documentation for the complete electrical protection requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompressor \u0026amp; Refrigeration\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Type:\u003c\/strong\u003e Twin-Rotary\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Model:\u003c\/strong\u003e ETPQ480D66UMU1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R454B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Refrigerant Charge:\u003c\/strong\u003e 183.42 oz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant Oil:\u003c\/strong\u003e VG75\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant Oil Charge:\u003c\/strong\u003e 1,300 mL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpansion Device:\u003c\/strong\u003e Electronic Expansion Valve\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePiping Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Flared\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid Pipe Size:\u003c\/strong\u003e 3\/8 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Pipe Size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Piping Length:\u003c\/strong\u003e 246 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Height Difference:\u003c\/strong\u003e 98 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Pre-Charged Piping Length:\u003c\/strong\u003e 24.6 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Refrigerant:\u003c\/strong\u003e 0.7 oz\/ft\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOperating Conditions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Operating Range:\u003c\/strong\u003e -22°F to 122°F (-30°C to 50°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Operating Range:\u003c\/strong\u003e -22°F to 75°F (-30°C to 24°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heating:\u003c\/strong\u003e Down to -22°F (-30°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOutdoor Unit Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit:\u003c\/strong\u003e CU-HM55BAHU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H × W × D):\u003c\/strong\u003e 52-1\/2 × 37-1\/2 × 16-3\/8 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H × W × D):\u003c\/strong\u003e 1333 × 952 × 415 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 242.95 lb \/ approximately 110.2 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGross Weight:\u003c\/strong\u003e 275 lb \/ approximately 124.8 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Airflow:\u003c\/strong\u003e 2,649 CFM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Noise Level:\u003c\/strong\u003e 64 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompatible A-Coil Indoor Units\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCS-HM60BAAU4\u003c\/li\u003e\n\u003cli\u003eCS-HM60BAMU3\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHybrid Heating Application\u003c\/h2\u003e\n\u003cp\u003eThe CU-HM55BAHU is designed for central ducted hybrid dual-fuel applications. When paired with a compatible INTERIOS A-coil, the heat pump can work with a new or existing furnace to provide whole-home heating and cooling. Panasonic's INTERIOS Extreme Heat platform is designed for cold-climate operation down to -22°F (-30°C).\u003c\/p\u003e\n\n\u003ch2\u003eRefrigerant \u0026amp; System Safety\u003c\/h2\u003e\n\u003cp\u003eThe system uses R454B refrigerant. Panasonic's compatible A-coil platform incorporates an A2L refrigerant sensor and is designed for cold-climate operation with a built-in base pan. The CU-HM55BAHU is also listed by Panasonic as an ENERGY STAR Cold Climate compatible system component when used in qualifying system combinations.\u003c\/p\u003e\n\n\u003ch2\u003eSystem Compatibility Note\u003c\/h2\u003e\n\u003cp\u003ePerformance ratings vary depending on the indoor A-coil combination. The specifications above distinguish the CU-HM55BAHU outdoor-unit data from the published system ratings for the CS-HM60BAAU4 hybrid A-coil combination. Always use the applicable Panasonic\/AHRI submittal for final installation and certification data.\u003c\/p\u003e","brand":"Panasonic Products","offers":[{"title":"Default Title","offer_id":44875447599284,"sku":"kpi261-CU-HM55BAHU","price":7983.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0645\/8484\/3444\/files\/CS-HM60BAAU4.png?v=1789910704"},{"product_id":"panasonic-cs-hm24baau1-interios-1-5-ton-a-coil-heat-pump","title":"Panasonic CS-HM24BAAU1 INTERIOS 1.5 Ton A-Coil Heat Pump","description":"\u003cp\u003eThe Panasonic INTERIOS CS-HM24BAAU1 is a multi-position A-coil indoor unit designed for hybrid heating and cooling applications. When paired with the CU-HM18BAHU outdoor Extreme Heat Pump, it forms a 1.5-ton dual-fuel heat pump system that integrates with a new or existing furnace for whole-home heating and cooling. The system uses R454B refrigerant and is designed for cold-climate operation down to -22°F.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1.5-ton hybrid A-coil heat pump system\u003c\/li\u003e\n\u003cli\u003eCompatible with CU-HM18BAHU 18,000 BTU\/h outdoor heat pump\u003c\/li\u003e\n\u003cli\u003eAlso compatible with CU-HM24BAHU 24,000 BTU\/h outdoor heat pump\u003c\/li\u003e\n\u003cli\u003eDesigned to integrate with a new or existing furnace\u003c\/li\u003e\n\u003cli\u003eMulti-position A-coil design\u003c\/li\u003e\n\u003cli\u003eR454B refrigerant\u003c\/li\u003e\n\u003cli\u003eENERGY STAR Cold Climate certified\u003c\/li\u003e\n\u003cli\u003eHeating operation down to -22°F (-30°C)\u003c\/li\u003e\n\u003cli\u003eBuilt-in A2L refrigerant sensor\u003c\/li\u003e\n\u003cli\u003eEasy-maintenance design\u003c\/li\u003e\n\u003cli\u003eEXV electronic expansion valve\u003c\/li\u003e\n\u003cli\u003eFlared refrigerant connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSystem Performance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Unit: CS-HM24BAAU1\u003c\/li\u003e\n\u003cli\u003eOutdoor Unit: CU-HM18BAHU\u003c\/li\u003e\n\u003cli\u003eRated Cooling Capacity: 18,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCooling Capacity Range: 5,600–22,800 BTU\/h\u003c\/li\u003e\n\u003cli\u003eRated Heating Capacity at 47°F: 19,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity Range at 47°F: 5,600–22,800 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 17°F: 15,200 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 5°F: 18,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eMaximum Heating Capacity at 5°F: 18,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCOP at 5°F: 2.06\u003c\/li\u003e\n\u003cli\u003eCooling Moisture Removal: 2.05 L\/h\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eEfficiency Ratings\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSEER2: 16.1\u003c\/li\u003e\n\u003cli\u003eEER2: 11.7\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region IV: 9.5\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region V: 7.8\u003c\/li\u003e\n\u003cli\u003eCOP: 3.30\u003c\/li\u003e\n\u003cli\u003eENERGY STAR Certified: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIndoor A-Coil Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Indoor A-Coil Heat Pump Unit\u003c\/li\u003e\n\u003cli\u003eInstallation Type: Multi-position\u003c\/li\u003e\n\u003cli\u003eIndoor Power Supply: 24V, 1 Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eThrottle Type: EXV\u003c\/li\u003e\n\u003cli\u003eRefrigerant Sensor: A2L sensor included\u003c\/li\u003e\n\u003cli\u003eIndoor Dimensions (W x D x H): 14.49 x 21.00 x 17.99 in\u003c\/li\u003e\n\u003cli\u003eIndoor Dimensions (W x D x H): 368 x 533.4 x 457 mm\u003c\/li\u003e\n\u003cli\u003eNet Weight: 41.89 lb (19 kg)\u003c\/li\u003e\n\u003cli\u003eGross Weight: 49.60 lb (22.5 kg)\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions (W x D x H): 17.52 x 25.39 x 20.67 in\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions (W x D x H): 445 x 645 x 525 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOutdoor Heat Pump Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Unit: CU-HM18BAHU\u003c\/li\u003e\n\u003cli\u003eCompressor Type: Rotary\u003c\/li\u003e\n\u003cli\u003eCompressor Model: KTM240D46UKT2\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil: VG74\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil Charge: 620 mL\u003c\/li\u003e\n\u003cli\u003eMaximum Outdoor Airflow: 1,766 CFM\u003c\/li\u003e\n\u003cli\u003eOutdoor Noise Level: 58 dBA\u003c\/li\u003e\n\u003cli\u003eOutdoor Dimensions (W x D x H): 35.04 x 13.46 x 26.50 in\u003c\/li\u003e\n\u003cli\u003eOutdoor Dimensions (W x D x H): 890 x 342 x 673 mm\u003c\/li\u003e\n\u003cli\u003eOutdoor Net Weight: 101.41 lb (46 kg)\u003c\/li\u003e\n\u003cli\u003eOutdoor Gross Weight: 109.13 lb (49.5 kg)\u003c\/li\u003e\n\u003cli\u003eOutdoor Package Dimensions (W x D x H): 39.17 x 15.67 x 29.13 in\u003c\/li\u003e\n\u003cli\u003eOutdoor Package Dimensions (W x D x H): 995 x 398 x 740 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Power Supply: 24V, 1 Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eOutdoor Power Supply: 208\/230V, 1 Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eOutdoor MCA: 16 A\u003c\/li\u003e\n\u003cli\u003eOutdoor MOP: 20 A\u003c\/li\u003e\n\u003cli\u003eCompressor RLA: 10.5 A\u003c\/li\u003e\n\u003cli\u003eOutdoor Fan Motor RLA: 0.9 A\u003c\/li\u003e\n\u003cli\u003eCommunication Wiring: AWG 20-2\u003c\/li\u003e\n\u003cli\u003eCooling System Power Input: 1,538 W rated (530–2,120 W)\u003c\/li\u003e\n\u003cli\u003eHeating System Power Input: 1,687 W rated (350–2,040 W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eRefrigerant and Piping Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eLiquid Line Size: 3\/8 in (9.52 mm)\u003c\/li\u003e\n\u003cli\u003eGas Line Size: 3\/4 in (19 mm)\u003c\/li\u003e\n\u003cli\u003eConnection Method: Flared\u003c\/li\u003e\n\u003cli\u003eIndoor Throttle: EXV\u003c\/li\u003e\n\u003cli\u003eOutdoor Throttle: EXV\u003c\/li\u003e\n\u003cli\u003eMaximum Piping Length: 98 ft (30 m)\u003c\/li\u003e\n\u003cli\u003eMaximum Height Difference: 66 ft (20 m)\u003c\/li\u003e\n\u003cli\u003eMaximum Pre-Charged Length: 24.6 ft (7.5 m)\u003c\/li\u003e\n\u003cli\u003eFactory Refrigerant Charge: 74.08 oz (2.1 kg)\u003c\/li\u003e\n\u003cli\u003eAdditional Refrigerant Charge: 0.7 oz\/ft (65 g\/m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOperating Conditions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCooling Indoor Operating Range: 60°F to 90°F (16°C to 32°C)\u003c\/li\u003e\n\u003cli\u003eCooling Outdoor Operating Range: -22°F to 122°F (-30°C to 50°C)\u003c\/li\u003e\n\u003cli\u003eHeating Indoor Operating Range: 32°F to 86°F (0°C to 30°C)\u003c\/li\u003e\n\u003cli\u003eHeating Outdoor Operating Range: -22°F to 75°F (-30°C to 24°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHybrid heating and cooling\u003c\/li\u003e\n\u003cli\u003eDual-fuel HVAC system\u003c\/li\u003e\n\u003cli\u003eCentral ducted whole-home heating and cooling\u003c\/li\u003e\n\u003cli\u003eDesigned to integrate with a new or existing furnace\u003c\/li\u003e\n\u003cli\u003eMulti-position A-coil installation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Panasonic Products","offers":[{"title":"Default Title","offer_id":44875448254644,"sku":"kpi261-CS-HM24BAAU1","price":1260.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0645\/8484\/3444\/files\/CS-HM24BAAU1.png?v=1789910702"},{"product_id":"panasonic-cs-hm24baau2-interios-1-5-2-ton-a-coil-heat-pump","title":"Panasonic CS-HM24BAAU2 INTERIOS 1.5–2 Ton A-Coil Heat Pump","description":"\u003cp\u003eThe Panasonic INTERIOS CS-HM24BAAU2 is a multi-position A-coil indoor unit designed for hybrid heating and cooling applications. It integrates with a new or existing furnace to provide whole-home heating and cooling. The A-coil can be paired with either the CU-HM18BAHU 18,000 BTU\/h outdoor heat pump for a 1.5-ton system or the CU-HM24BAHU 24,000 BTU\/h outdoor heat pump for a 2-ton system.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1.5–2 ton hybrid A-coil heat pump system\u003c\/li\u003e\n\u003cli\u003eCompatible with CU-HM18BAHU and CU-HM24BAHU outdoor units\u003c\/li\u003e\n\u003cli\u003eDesigned to integrate with a new or existing furnace\u003c\/li\u003e\n\u003cli\u003eMulti-position installation design\u003c\/li\u003e\n\u003cli\u003eR454B refrigerant\u003c\/li\u003e\n\u003cli\u003eENERGY STAR Cold Climate certified\u003c\/li\u003e\n\u003cli\u003eHeating operation down to -22°F (-30°C)\u003c\/li\u003e\n\u003cli\u003eBuilt-in A2L refrigerant sensor\u003c\/li\u003e\n\u003cli\u003eEasy-maintenance design\u003c\/li\u003e\n\u003cli\u003eAluminum coil construction\u003c\/li\u003e\n\u003cli\u003eEXV electronic expansion valve\u003c\/li\u003e\n\u003cli\u003eMultiple control options available\u003c\/li\u003e\n\u003cli\u003eThird-party 24V thermostat compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIndoor A-Coil Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Model: CS-HM24BAAU2\u003c\/li\u003e\n\u003cli\u003eProduct Type: Cased A-Coil Heat Pump\u003c\/li\u003e\n\u003cli\u003eSystem Application: Hybrid \/ Dual-Fuel Heating and Cooling\u003c\/li\u003e\n\u003cli\u003eInstallation: Multi-position, horizontal or vertical\u003c\/li\u003e\n\u003cli\u003eIndoor Power Supply: 24V, 1 Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eIndoor Dimensions (W x D x H): 17.52 x 21.00 x 17.99 in\u003c\/li\u003e\n\u003cli\u003eIndoor Dimensions (W x D x H): 445 x 533.4 x 457 mm\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions (W x D x H): 20.47 x 26.18 x 20.87 in\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions (W x D x H): 520 x 665 x 530 mm\u003c\/li\u003e\n\u003cli\u003eNet Weight: 41.89 lb (19 kg)\u003c\/li\u003e\n\u003cli\u003eGross Weight: 49.60 lb (22.5 kg)\u003c\/li\u003e\n\u003cli\u003eIndoor Airflow: Not specified in the Panasonic submittal\u003c\/li\u003e\n\u003cli\u003eIndoor Noise Level: Not specified in the Panasonic submittal\u003c\/li\u003e\n\u003cli\u003eESP: Not specified in the Panasonic submittal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eConfiguration 1 – 1.5 Ton System\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Unit: CU-HM18BAHU\u003c\/li\u003e\n\u003cli\u003eRated Cooling Capacity: 18,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCooling Capacity Range: 5,600–22,800 BTU\/h\u003c\/li\u003e\n\u003cli\u003eRated Heating Capacity at 47°F: 19,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity Range at 47°F: 5,600–22,800 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 17°F: 15,200 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 5°F: 18,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCOP at 5°F: 2.06\u003c\/li\u003e\n\u003cli\u003eCooling Moisture Removal: 2.05 L\/h\u003c\/li\u003e\n\u003cli\u003eSEER2: 16.1\u003c\/li\u003e\n\u003cli\u003eEER2: 11.7\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region IV: 9.5\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region V: 7.8\u003c\/li\u003e\n\u003cli\u003eCOP: 3.3\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eConfiguration 2 – 2 Ton System\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Unit: CU-HM24BAHU\u003c\/li\u003e\n\u003cli\u003eRated Cooling Capacity: 24,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCooling Capacity Range: 7,900–27,600 BTU\/h\u003c\/li\u003e\n\u003cli\u003eRated Heating Capacity at 47°F: 25,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity Range at 47°F: 6,500–30,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 17°F: 19,700 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 5°F: 21,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCOP at 5°F: 1.8\u003c\/li\u003e\n\u003cli\u003eCooling Moisture Removal: 2.89 L\/h\u003c\/li\u003e\n\u003cli\u003eSEER2: 16.0\u003c\/li\u003e\n\u003cli\u003eEER2: 10.0\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region IV: 9.5\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region V: 7.0\u003c\/li\u003e\n\u003cli\u003eCOP: 3.2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOutdoor Unit – CU-HM18BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCompressor Type: Rotary\u003c\/li\u003e\n\u003cli\u003eCompressor Model: KTM240D46UKT2\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil: VG74\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil Charge: 620 mL\u003c\/li\u003e\n\u003cli\u003eMaximum Outdoor Airflow: 1,766 CFM\u003c\/li\u003e\n\u003cli\u003eOutdoor Noise Level: 58 dBA\u003c\/li\u003e\n\u003cli\u003eDimensions (W x D x H): 35.04 x 13.46 x 26.50 in\u003c\/li\u003e\n\u003cli\u003eDimensions (W x D x H): 890 x 342 x 673 mm\u003c\/li\u003e\n\u003cli\u003eNet\/Gross Weight: 101.41 \/ 109.13 lb\u003c\/li\u003e\n\u003cli\u003eNet\/Gross Weight: 46 \/ 49.5 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOutdoor Unit – CU-HM24BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCompressor Type: Rotary\u003c\/li\u003e\n\u003cli\u003eCompressor Model: KTM240D46UKT2\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil: VG74\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil Charge: 620 mL\u003c\/li\u003e\n\u003cli\u003eMaximum Outdoor Airflow: 1,766 CFM\u003c\/li\u003e\n\u003cli\u003eOutdoor Noise Level: 60 dBA\u003c\/li\u003e\n\u003cli\u003eDimensions (W x D x H): 35.04 x 13.46 x 26.50 in\u003c\/li\u003e\n\u003cli\u003eDimensions (W x D x H): 890 x 342 x 673 mm\u003c\/li\u003e\n\u003cli\u003eNet\/Gross Weight: 101.41 \/ 109.13 lb\u003c\/li\u003e\n\u003cli\u003eNet\/Gross Weight: 46 \/ 49.5 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications – CU-HM18BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Power Supply: 24V, 1 Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eOutdoor Power Supply: 208\/230V, 1 Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eOutdoor MCA: 16 A\u003c\/li\u003e\n\u003cli\u003eOutdoor MOP: 20 A\u003c\/li\u003e\n\u003cli\u003eCompressor RLA: 10.5 A\u003c\/li\u003e\n\u003cli\u003eOutdoor Fan Motor RLA: 0.9 A\u003c\/li\u003e\n\u003cli\u003eCommunication Wiring: AWG 20-2\u003c\/li\u003e\n\u003cli\u003eCooling System Power Input: 1,538 W rated (530–2,120 W)\u003c\/li\u003e\n\u003cli\u003eHeating System Power Input: 1,687 W rated (350–2,040 W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications – CU-HM24BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Power Supply: 24V, 1 Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eOutdoor Power Supply: 208\/230V, 1 Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eOutdoor MCA: 19 A\u003c\/li\u003e\n\u003cli\u003eOutdoor MOP: 20 A\u003c\/li\u003e\n\u003cli\u003eCompressor RLA: 14 A\u003c\/li\u003e\n\u003cli\u003eOutdoor Fan Motor RLA: 1 A\u003c\/li\u003e\n\u003cli\u003eCommunication Wiring: AWG 20-2\u003c\/li\u003e\n\u003cli\u003eCooling System Power Input: 2,400 W rated (680–2,890 W)\u003c\/li\u003e\n\u003cli\u003eHeating System Power Input: 2,290 W rated (330–2,900 W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eRefrigerant and Piping – CU-HM18BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eLiquid Line Size: 3\/8 in (9.52 mm)\u003c\/li\u003e\n\u003cli\u003eGas Line Size: 3\/4 in (19 mm)\u003c\/li\u003e\n\u003cli\u003eConnection Method: Flared\u003c\/li\u003e\n\u003cli\u003eIndoor Throttle Type: EXV\u003c\/li\u003e\n\u003cli\u003eOutdoor Throttle Type: EXV\u003c\/li\u003e\n\u003cli\u003eMaximum Piping Length: 98 ft (30 m)\u003c\/li\u003e\n\u003cli\u003eMaximum Height Difference: 82 ft (25 m)\u003c\/li\u003e\n\u003cli\u003eMaximum Pre-Charged Length: 24.6 ft (7.5 m)\u003c\/li\u003e\n\u003cli\u003eFactory Refrigerant Charge: 74.08 oz (2.1 kg)\u003c\/li\u003e\n\u003cli\u003eAdditional Refrigerant: 0.7 oz\/ft (65 g\/m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eRefrigerant and Piping – CU-HM24BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eLiquid Line Size: 3\/8 in (9.52 mm)\u003c\/li\u003e\n\u003cli\u003eGas Line Size: 3\/4 in (19 mm)\u003c\/li\u003e\n\u003cli\u003eConnection Method: Flared\u003c\/li\u003e\n\u003cli\u003eIndoor Throttle Type: EXV\u003c\/li\u003e\n\u003cli\u003eOutdoor Throttle Type: EXV\u003c\/li\u003e\n\u003cli\u003eMaximum Piping Length: 164 ft (50 m)\u003c\/li\u003e\n\u003cli\u003eMaximum Height Difference: 82 ft (25 m)\u003c\/li\u003e\n\u003cli\u003eMaximum Pre-Charged Length: 24.6 ft (7.5 m)\u003c\/li\u003e\n\u003cli\u003eFactory Refrigerant Charge: 74.08 oz (2.1 kg)\u003c\/li\u003e\n\u003cli\u003eAdditional Refrigerant: 0.7 oz\/ft (65 g\/m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOperating Conditions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCooling Outdoor Operating Range: -22°F to 122°F (-30°C to 50°C)\u003c\/li\u003e\n\u003cli\u003eHeating Outdoor Operating Range: -22°F to 75°F (-30°C to 24°C)\u003c\/li\u003e\n\u003cli\u003eCold Climate Heating Operation: Down to -22°F (-30°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eControls and Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHybrid heating and cooling\u003c\/li\u003e\n\u003cli\u003eDual-fuel HVAC system\u003c\/li\u003e\n\u003cli\u003eCentral ducted whole-home heating and cooling\u003c\/li\u003e\n\u003cli\u003eCompatible with a new or existing furnace\u003c\/li\u003e\n\u003cli\u003eTwo-way communication wired controller with built-in Wi-Fi option\u003c\/li\u003e\n\u003cli\u003eThird-party 24V thermostat compatibility\u003c\/li\u003e\n\u003cli\u003eBuilt-in R454B A2L refrigerant sensor\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Panasonic Products","offers":[{"title":"Default Title","offer_id":44875448287412,"sku":"kpi261-CS-HM24BAAU2","price":1365.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0645\/8484\/3444\/files\/CS-HM24BAAU1_44bc3f17-3711-48d9-ae29-f2268b337f9b.png?v=1789910704"},{"product_id":"panasonic-cs-hm36baau1-interios-2-5-3-ton-a-coil-heat-pump","title":"Panasonic CS-HM36BAAU1 INTERIOS 2.5–3 Ton A-Coil Heat Pump","description":"\u003cp\u003eThe Panasonic INTERIOS CS-HM36BAAU1 is a multi-position A-coil indoor unit designed for hybrid heating and cooling applications. It integrates with a new or existing furnace to provide whole-home heating and cooling. The A-coil is compatible with either the CU-HM30BAHU 2.5-ton outdoor heat pump or the CU-HM36BAHU 3-ton outdoor heat pump and uses R454B refrigerant.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e2.5–3 ton hybrid A-coil heat pump system\u003c\/li\u003e\n\u003cli\u003eCompatible with CU-HM30BAHU and CU-HM36BAHU outdoor units\u003c\/li\u003e\n\u003cli\u003eDesigned to integrate with a new or existing furnace\u003c\/li\u003e\n\u003cli\u003eMulti-position installation design\u003c\/li\u003e\n\u003cli\u003eR454B refrigerant\u003c\/li\u003e\n\u003cli\u003eENERGY STAR Cold Climate certified\u003c\/li\u003e\n\u003cli\u003eHeating operation down to -22°F (-30°C)\u003c\/li\u003e\n\u003cli\u003eBuilt-in A2L refrigerant sensor\u003c\/li\u003e\n\u003cli\u003eEasy-maintenance design\u003c\/li\u003e\n\u003cli\u003eEXV electronic expansion valve\u003c\/li\u003e\n\u003cli\u003eFlared refrigerant connections\u003c\/li\u003e\n\u003cli\u003eDual-fuel central ducted application\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIndoor A-Coil Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Model: CS-HM36BAAU1\u003c\/li\u003e\n\u003cli\u003eProduct Type: Cased A-Coil Heat Pump\u003c\/li\u003e\n\u003cli\u003eSystem Application: Hybrid \/ Dual-Fuel Heating and Cooling\u003c\/li\u003e\n\u003cli\u003eInstallation: Multi-position\u003c\/li\u003e\n\u003cli\u003eIndoor Power Supply: 24V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eIndoor Dimensions (W x D x H): 14.49 x 21.00 x 17.99 in\u003c\/li\u003e\n\u003cli\u003eIndoor Dimensions (W x D x H): 368 x 533.4 x 457 mm\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions (W x D x H): 17.52 x 25.39 x 20.67 in\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions (W x D x H): 445 x 645 x 525 mm\u003c\/li\u003e\n\u003cli\u003eNet Weight: 56.88 lb (25.8 kg)\u003c\/li\u003e\n\u003cli\u003eGross Weight: 64.81 lb (29.4 kg)\u003c\/li\u003e\n\u003cli\u003eThrottle Type: EXV\u003c\/li\u003e\n\u003cli\u003eRefrigerant Sensor: A2L sensor included\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eConfiguration 1 – 2.5 Ton System\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Unit: CU-HM30BAHU\u003c\/li\u003e\n\u003cli\u003eRated Cooling Capacity: 30,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCooling Capacity Range: 12,600–34,800 BTU\/h\u003c\/li\u003e\n\u003cli\u003eRated Heating Capacity at 47°F: 30,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity Range at 47°F: 9,300–35,900 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 17°F: 23,400 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 5°F: 30,400 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCOP at 5°F: 1.8\u003c\/li\u003e\n\u003cli\u003eCooling Moisture Removal: 4.56 L\/h\u003c\/li\u003e\n\u003cli\u003eSEER2: 15.3\u003c\/li\u003e\n\u003cli\u003eEER2: 10.0\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region IV: 9.3\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region V: 7.7\u003c\/li\u003e\n\u003cli\u003eCOP: 3.0\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eConfiguration 2 – 3 Ton System\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Unit: CU-HM36BAHU\u003c\/li\u003e\n\u003cli\u003eRated Cooling Capacity: 36,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCooling Capacity Range: 11,400–39,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eRated Heating Capacity at 47°F: 38,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity Range at 47°F: 11,500–46,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eSEER2: 15.2\u003c\/li\u003e\n\u003cli\u003eEER2: 10.2\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region IV: 9.0\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region V: 7.2\u003c\/li\u003e\n\u003cli\u003eCOP: 3.1\u003c\/li\u003e\n\u003cli\u003eOutdoor Noise Level: 64 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOutdoor Unit – CU-HM30BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCompressor Type: Rotary\u003c\/li\u003e\n\u003cli\u003eCompressor Model: MTH356UKRC8FQL\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil: HAF68D1A\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil Charge: 1,300 mL\u003c\/li\u003e\n\u003cli\u003eMaximum Outdoor Airflow: 3,002 CFM\u003c\/li\u003e\n\u003cli\u003eOutdoor Noise Level: 64 dBA\u003c\/li\u003e\n\u003cli\u003eDimensions (W x D x H): 37.24 x 16.14 x 31.89 in\u003c\/li\u003e\n\u003cli\u003eDimensions (W x D x H): 946 x 410 x 810 mm\u003c\/li\u003e\n\u003cli\u003eNet\/Gross Weight: 164.02 \/ 174.60 lb\u003c\/li\u003e\n\u003cli\u003eNet\/Gross Weight: 74.4 \/ 79.2 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications – CU-HM30BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Power Supply: 208\/230V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eOutdoor MCA: 29.5 A\u003c\/li\u003e\n\u003cli\u003eOutdoor MOP: 30 A\u003c\/li\u003e\n\u003cli\u003eCompressor RLA: 22.4 A\u003c\/li\u003e\n\u003cli\u003eOutdoor Fan Motor RLA: 1.5 A\u003c\/li\u003e\n\u003cli\u003eCommunication Wiring: AWG 20-2\u003c\/li\u003e\n\u003cli\u003eCooling System Power Input: 3,000 W rated (1,160–3,680 W)\u003c\/li\u003e\n\u003cli\u003eHeating System Power Input: 2,931 W rated (540–3,590 W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eRefrigerant and Piping – CU-HM30BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eLiquid Line Size: 3\/8 in (9.52 mm)\u003c\/li\u003e\n\u003cli\u003eGas Line Size: 3\/4 in (19 mm)\u003c\/li\u003e\n\u003cli\u003eConnection Method: Flared\u003c\/li\u003e\n\u003cli\u003eIndoor Throttle: EXV\u003c\/li\u003e\n\u003cli\u003eOutdoor Throttle: EXV\u003c\/li\u003e\n\u003cli\u003eMaximum Piping Length: 164 ft (50 m)\u003c\/li\u003e\n\u003cli\u003eMaximum Height Difference: 82 ft (25 m)\u003c\/li\u003e\n\u003cli\u003eMaximum Pre-Charged Length: 24.6 ft (7.5 m)\u003c\/li\u003e\n\u003cli\u003eFactory Refrigerant Charge: 105.82 oz (3 kg)\u003c\/li\u003e\n\u003cli\u003eAdditional Refrigerant: 0.7 oz\/ft (65 g\/m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOperating Conditions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCooling Outdoor Operating Range: -22°F to 122°F (-30°C to 50°C)\u003c\/li\u003e\n\u003cli\u003eHeating Outdoor Operating Range: -22°F to 75°F (-30°C to 24°C)\u003c\/li\u003e\n\u003cli\u003eCold Climate Heating Operation: Down to -22°F (-30°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHybrid heating and cooling\u003c\/li\u003e\n\u003cli\u003eDual-fuel HVAC system\u003c\/li\u003e\n\u003cli\u003eCentral ducted whole-home heating and cooling\u003c\/li\u003e\n\u003cli\u003eIntegration with new or existing furnace\u003c\/li\u003e\n\u003cli\u003eMulti-position A-coil installation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Panasonic Products","offers":[{"title":"Default Title","offer_id":44875448320180,"sku":"kpi261-CS-HM36BAAU1","price":1421.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0645\/8484\/3444\/files\/CS-HM24BAAU1_f3af2eb2-fb38-402f-9f5f-37076e46447a.png?v=1789910703"},{"product_id":"panasonic-cs-hm36baau2-interios-2-5-3-ton-a-coil-heat-pump","title":"Panasonic CS-HM36BAAU2 INTERIOS 2.5–3 Ton A-Coil Heat Pump","description":"\u003cp\u003eThe Panasonic INTERIOS CS-HM36BAAU2 is a multi-position cased A-coil designed for hybrid heating and cooling applications. It integrates with a new or existing furnace to provide whole-home heating and cooling. The A-coil is compatible with Panasonic CU-HM30BAHU and CU-HM36BAHU outdoor heat pump units and uses R454B refrigerant for cold-climate operation.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e2.5–3 ton hybrid A-coil heat pump system\u003c\/li\u003e\n\u003cli\u003eCompatible with CU-HM30BAHU and CU-HM36BAHU outdoor units\u003c\/li\u003e\n\u003cli\u003eDesigned for integration with a new or existing furnace\u003c\/li\u003e\n\u003cli\u003eMulti-position installation design\u003c\/li\u003e\n\u003cli\u003eR454B refrigerant\u003c\/li\u003e\n\u003cli\u003eENERGY STAR Cold Climate certified\u003c\/li\u003e\n\u003cli\u003eHeating operation down to -22°F (-30°C)\u003c\/li\u003e\n\u003cli\u003eBuilt-in A2L refrigerant sensor\u003c\/li\u003e\n\u003cli\u003eEasy-maintenance design\u003c\/li\u003e\n\u003cli\u003eEXV electronic expansion valve\u003c\/li\u003e\n\u003cli\u003eFlared refrigerant connections\u003c\/li\u003e\n\u003cli\u003eCentral ducted hybrid \/ dual-fuel application\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIndoor A-Coil Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Model: CS-HM36BAAU2\u003c\/li\u003e\n\u003cli\u003eProduct Type: Cased A-Coil Heat Pump\u003c\/li\u003e\n\u003cli\u003eApplication: Hybrid \/ Dual-Fuel Heating and Cooling\u003c\/li\u003e\n\u003cli\u003eInstallation: Multi-position\u003c\/li\u003e\n\u003cli\u003eIndoor Power Supply: 24V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eThrottle Type: EXV\u003c\/li\u003e\n\u003cli\u003eA2L Refrigerant Sensor: Included\u003c\/li\u003e\n\u003cli\u003eIndoor Dimensions (W x D x H): 17.52 x 21.00 x 17.99 in\u003c\/li\u003e\n\u003cli\u003eIndoor Dimensions (W x D x H): 445 x 533.4 x 457 mm\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions (W x D x H): 20.47 x 26.18 x 20.87 in\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions (W x D x H): 520 x 665 x 530 mm\u003c\/li\u003e\n\u003cli\u003eNet Weight: 59.52 lb (27 kg)\u003c\/li\u003e\n\u003cli\u003eGross Weight: 68.12 lb (30.9 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e3 Ton Configuration – CU-HM36BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Unit: CU-HM36BAHU\u003c\/li\u003e\n\u003cli\u003eRated Cooling Capacity: 36,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCooling Capacity Range: 12,100–41,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eRated Heating Capacity at 47°F: 38,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity Range at 47°F: 11,500–46,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 17°F: 29,200 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 5°F: 36,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eMaximum Heating Capacity at 5°F: 36,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCOP at 5°F: 1.9\u003c\/li\u003e\n\u003cli\u003eCooling Moisture Removal: 4.91 L\/h\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eEfficiency Ratings – 3 Ton Configuration\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSEER2: 15.8\u003c\/li\u003e\n\u003cli\u003eEER2: 10.7\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region IV: 9.4\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region V: 7.9\u003c\/li\u003e\n\u003cli\u003eCOP: 3.3\u003c\/li\u003e\n\u003cli\u003eENERGY STAR Certified: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOutdoor Unit Specifications – CU-HM36BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Unit: CU-HM36BAHU\u003c\/li\u003e\n\u003cli\u003eCompressor Type: Rotary\u003c\/li\u003e\n\u003cli\u003eCompressor Model: EKPQ420D1UMUA\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil: VG75\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil Charge: 1,460 mL\u003c\/li\u003e\n\u003cli\u003eMaximum Outdoor Airflow: 3,002 CFM\u003c\/li\u003e\n\u003cli\u003eOutdoor Noise Level: 64 dBA\u003c\/li\u003e\n\u003cli\u003eOutdoor Dimensions (W x D x H): 38.58 x 16.34 x 38.39 in\u003c\/li\u003e\n\u003cli\u003eOutdoor Dimensions (W x D x H): 980 x 415 x 975 mm\u003c\/li\u003e\n\u003cli\u003eOutdoor Net Weight: 204.15 lb (92.6 kg)\u003c\/li\u003e\n\u003cli\u003eOutdoor Gross Weight: 235.23 lb (106.7 kg)\u003c\/li\u003e\n\u003cli\u003eOutdoor Package Dimensions (W x D x H): 45.08 x 19.69 x 42.52 in\u003c\/li\u003e\n\u003cli\u003eOutdoor Package Dimensions (W x D x H): 1,145 x 500 x 1,080 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications – CU-HM36BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Power Supply: 24V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eOutdoor Power Supply: 208\/230V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eOutdoor MCA: 29 A\u003c\/li\u003e\n\u003cli\u003eOutdoor MOP: 30 A\u003c\/li\u003e\n\u003cli\u003eCompressor RLA: 20.5 A\u003c\/li\u003e\n\u003cli\u003eOutdoor Fan Motor RLA: 2.4 A\u003c\/li\u003e\n\u003cli\u003eCommunication Wiring: AWG 20-2\u003c\/li\u003e\n\u003cli\u003eCooling System Power Input: 3,364 W rated (1,020–4,520 W)\u003c\/li\u003e\n\u003cli\u003eHeating System Power Input: 3,375 W rated (800–4,540 W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eRefrigerant and Piping Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eLiquid Line Size: 3\/8 in (9.52 mm)\u003c\/li\u003e\n\u003cli\u003eGas Line Size: 3\/4 in (19 mm)\u003c\/li\u003e\n\u003cli\u003eConnection Method: Flared\u003c\/li\u003e\n\u003cli\u003eIndoor Throttle Type: EXV\u003c\/li\u003e\n\u003cli\u003eOutdoor Throttle Type: EXV\u003c\/li\u003e\n\u003cli\u003eMaximum Piping Length: 246 ft (75 m)\u003c\/li\u003e\n\u003cli\u003eMaximum Height Difference: 98 ft (30 m)\u003c\/li\u003e\n\u003cli\u003eMaximum Pre-Charged Length: 24.6 ft (7.5 m)\u003c\/li\u003e\n\u003cli\u003eFactory Refrigerant Charge: 126.99 oz (3.6 kg)\u003c\/li\u003e\n\u003cli\u003eAdditional Refrigerant Charge: 0.7 oz\/ft (65 g\/m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOperating Conditions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCooling Outdoor Operating Range: -22°F to 122°F (-30°C to 50°C)\u003c\/li\u003e\n\u003cli\u003eHeating Outdoor Operating Range: -22°F to 75°F (-30°C to 24°C)\u003c\/li\u003e\n\u003cli\u003eCold Climate Heating Operation: Down to -22°F (-30°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHybrid heating and cooling\u003c\/li\u003e\n\u003cli\u003eDual-fuel HVAC system\u003c\/li\u003e\n\u003cli\u003eCentral ducted whole-home heating and cooling\u003c\/li\u003e\n\u003cli\u003eIntegration with a new or existing furnace\u003c\/li\u003e\n\u003cli\u003eMulti-position A-coil installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSystem Compatibility\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Unit: CS-HM36BAAU2\u003c\/li\u003e\n\u003cli\u003eCompatible Outdoor Units: CU-HM30BAHU and CU-HM36BAHU\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eSystem Type: INTERIOS Hybrid A-Coil Heat Pump\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Panasonic Products","offers":[{"title":"Default Title","offer_id":44875448352948,"sku":"kpi261-CS-HM36BAAU2","price":1495.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0645\/8484\/3444\/files\/CS-HM24BAAU1_69c26eec-b8d1-43d1-80b7-4141e1135087.png?v=1789910702"},{"product_id":"panasonic-cs-hm36baau3-interios-2-5-3-ton-a-coil-heat-pump","title":"Panasonic CS-HM36BAAU3 INTERIOS 2.5–3 Ton A-Coil Heat Pump","description":"\u003cp\u003eThe Panasonic INTERIOS CS-HM36BAAU3 is a multi-position cased A-coil designed for hybrid and dual-fuel heating and cooling systems. It integrates with a new or existing furnace and pairs with Panasonic CU-HM30BAHU or CU-HM36BAHU outdoor heat pump units. The system uses R454B refrigerant, includes an A2L refrigerant sensor, and is designed for cold-climate operation down to -22°F (-30°C).\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e2.5–3 ton hybrid A-coil heat pump system\u003c\/li\u003e\n\u003cli\u003eCompatible with CU-HM30BAHU and CU-HM36BAHU outdoor units\u003c\/li\u003e\n\u003cli\u003eDesigned for hybrid and dual-fuel HVAC applications\u003c\/li\u003e\n\u003cli\u003eIntegrates with a new or existing furnace\u003c\/li\u003e\n\u003cli\u003eMulti-position installation design\u003c\/li\u003e\n\u003cli\u003eR454B refrigerant\u003c\/li\u003e\n\u003cli\u003eENERGY STAR Cold Climate certified\u003c\/li\u003e\n\u003cli\u003eCold-climate heating operation down to -22°F (-30°C)\u003c\/li\u003e\n\u003cli\u003eBuilt-in A2L refrigerant sensor\u003c\/li\u003e\n\u003cli\u003eEXV electronic expansion valve\u003c\/li\u003e\n\u003cli\u003eEasy-maintenance design\u003c\/li\u003e\n\u003cli\u003eCentral ducted whole-home heating and cooling\u003c\/li\u003e\n\u003cli\u003eBuilt-in outdoor base pan for cold-climate operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIndoor A-Coil Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Model: CS-HM36BAAU3\u003c\/li\u003e\n\u003cli\u003eProduct Type: Cased A-Coil Heat Pump\u003c\/li\u003e\n\u003cli\u003eApplication: Hybrid \/ Dual-Fuel Heating and Cooling\u003c\/li\u003e\n\u003cli\u003eInstallation: Multi-position\u003c\/li\u003e\n\u003cli\u003eIndoor Power Supply: 24V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eThrottle Type: EXV\u003c\/li\u003e\n\u003cli\u003eA2L Refrigerant Sensor: Included\u003c\/li\u003e\n\u003cli\u003eIndoor Dimensions (W x D x H): 21.02 x 21.00 x 24.06 in\u003c\/li\u003e\n\u003cli\u003eIndoor Dimensions (W x D x H): 534 x 533.4 x 611 mm\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions (W x D x H): 24.02 x 26.18 x 26.97 in\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions (W x D x H): 610 x 665 x 685 mm\u003c\/li\u003e\n\u003cli\u003eNet Weight: 64.37 lb (29.2 kg)\u003c\/li\u003e\n\u003cli\u003eGross Weight: 74.07 lb (33.6 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e3 Ton Configuration – CU-HM36BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Unit: CU-HM36BAHU\u003c\/li\u003e\n\u003cli\u003eRated Cooling Capacity: 36,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCooling Capacity Range: 12,100–41,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eRated Heating Capacity at 47°F: 38,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity Range at 47°F: 11,500–46,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 17°F: 29,200 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 5°F: 36,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eMaximum Heating Capacity at 5°F: 36,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCOP at 5°F: 1.9\u003c\/li\u003e\n\u003cli\u003eMoisture Removal: 4.91 L\/h\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eEfficiency Ratings\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSEER2: 15.8\u003c\/li\u003e\n\u003cli\u003eEER2: 10.7\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region IV: 9.4\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region V: 7.9\u003c\/li\u003e\n\u003cli\u003eCOP: 3.3\u003c\/li\u003e\n\u003cli\u003eENERGY STAR Certified: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOutdoor Unit Specifications – CU-HM36BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Unit: CU-HM36BAHU\u003c\/li\u003e\n\u003cli\u003eCompressor Type: Rotary\u003c\/li\u003e\n\u003cli\u003eCompressor Model: EKPQ420D1UMUA\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil: VG75\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil Charge: 1,460 mL\u003c\/li\u003e\n\u003cli\u003eMaximum Outdoor Airflow: 3,002 CFM\u003c\/li\u003e\n\u003cli\u003eOutdoor Noise Level: 64 dBA\u003c\/li\u003e\n\u003cli\u003eOutdoor Dimensions (W x D x H): 38.58 x 16.34 x 38.39 in\u003c\/li\u003e\n\u003cli\u003eOutdoor Dimensions (W x D x H): 980 x 415 x 975 mm\u003c\/li\u003e\n\u003cli\u003eOutdoor Net Weight: 204.15 lb (92.6 kg)\u003c\/li\u003e\n\u003cli\u003eOutdoor Gross Weight: 235.23 lb (106.7 kg)\u003c\/li\u003e\n\u003cli\u003eOutdoor Package Dimensions (W x D x H): 45.08 x 19.69 x 42.52 in\u003c\/li\u003e\n\u003cli\u003eOutdoor Package Dimensions (W x D x H): 1,145 x 500 x 1,080 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Power Supply: 24V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eOutdoor Power Supply: 208\/230V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eOutdoor MCA: 29 A\u003c\/li\u003e\n\u003cli\u003eOutdoor MOP: 30 A\u003c\/li\u003e\n\u003cli\u003eCompressor RLA: 20.5 A\u003c\/li\u003e\n\u003cli\u003eOutdoor Fan Motor RLA: 2.4 A\u003c\/li\u003e\n\u003cli\u003eCommunication Wiring: AWG 20-2\u003c\/li\u003e\n\u003cli\u003eCooling System Power Input: 3,364 W rated (1,020–4,520 W)\u003c\/li\u003e\n\u003cli\u003eHeating System Power Input: 3,375 W rated (800–4,540 W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eRefrigerant and Piping Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eLiquid Line Size: 3\/8 in (9.52 mm)\u003c\/li\u003e\n\u003cli\u003eGas Line Size: 3\/4 in (19 mm)\u003c\/li\u003e\n\u003cli\u003eConnection Method: Flared\u003c\/li\u003e\n\u003cli\u003eIndoor Throttle Type: EXV\u003c\/li\u003e\n\u003cli\u003eOutdoor Throttle Type: EXV\u003c\/li\u003e\n\u003cli\u003eMaximum Piping Length: 246 ft (75 m)\u003c\/li\u003e\n\u003cli\u003eMaximum Height Difference: 98 ft (30 m)\u003c\/li\u003e\n\u003cli\u003eMaximum Pre-Charged Length: 24.6 ft (7.5 m)\u003c\/li\u003e\n\u003cli\u003eFactory Refrigerant Charge: 126.99 oz (3.6 kg)\u003c\/li\u003e\n\u003cli\u003eAdditional Refrigerant Charge: 0.7 oz\/ft (65 g\/m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOperating Conditions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCooling Outdoor Operating Range: -22°F to 122°F (-30°C to 50°C)\u003c\/li\u003e\n\u003cli\u003eHeating Outdoor Operating Range: -22°F to 75°F (-30°C to 24°C)\u003c\/li\u003e\n\u003cli\u003eCold Climate Heating Operation: Down to -22°F (-30°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHybrid heating and cooling\u003c\/li\u003e\n\u003cli\u003eDual-fuel HVAC system\u003c\/li\u003e\n\u003cli\u003eCentral ducted whole-home heating and cooling\u003c\/li\u003e\n\u003cli\u003eIntegration with a new or existing furnace\u003c\/li\u003e\n\u003cli\u003eMulti-position A-coil installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSystem Compatibility\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Unit: CS-HM36BAAU3\u003c\/li\u003e\n\u003cli\u003eCompatible Outdoor Units: CU-HM30BAHU and CU-HM36BAHU\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eSystem Type: Panasonic INTERIOS Hybrid A-Coil Heat Pump\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Panasonic Products","offers":[{"title":"Default Title","offer_id":44875448385716,"sku":"kpi261-CS-HM36BAAU3","price":1625.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0645\/8484\/3444\/files\/CS-HM24BAAU1_6b13b498-718e-452a-8e33-d8780b0e6ed5.png?v=1789910704"},{"product_id":"panasonic-cs-hm60bamu3-interios-4-5-ton-a-coil-heat-pump","title":"Panasonic CS-HM60BAMU3 INTERIOS 4–5 Ton A-Coil Heat Pump","description":"\u003cp\u003eThe Panasonic INTERIOS CS-HM60BAMU3 is a multi-position cased A-coil designed for hybrid and dual-fuel heating and cooling systems. It integrates with a new or existing furnace to provide whole-home heating and cooling. The A-coil is compatible with Panasonic CU-HM48BAHU and CU-HM55BAHU outdoor heat pump units and uses R454B refrigerant for cold-climate operation.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e4–5 ton hybrid A-coil heat pump system\u003c\/li\u003e\n\u003cli\u003eCompatible with CU-HM48BAHU and CU-HM55BAHU outdoor units\u003c\/li\u003e\n\u003cli\u003eDesigned for hybrid and dual-fuel HVAC applications\u003c\/li\u003e\n\u003cli\u003eIntegrates with a new or existing furnace\u003c\/li\u003e\n\u003cli\u003eMulti-position installation design\u003c\/li\u003e\n\u003cli\u003eR454B refrigerant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant sensor included\u003c\/li\u003e\n\u003cli\u003eCold-climate heating operation down to -22°F (-30°C)\u003c\/li\u003e\n\u003cli\u003eEXV electronic expansion valve\u003c\/li\u003e\n\u003cli\u003eEasy-maintenance design\u003c\/li\u003e\n\u003cli\u003eBuilt-in base pan for cold-climate operation\u003c\/li\u003e\n\u003cli\u003eCentral ducted whole-home heating and cooling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIndoor A-Coil Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Model: CS-HM60BAMU3\u003c\/li\u003e\n\u003cli\u003eProduct Type: Cased A-Coil Heat Pump\u003c\/li\u003e\n\u003cli\u003eApplication: Hybrid \/ Dual-Fuel Heating and Cooling\u003c\/li\u003e\n\u003cli\u003eInstallation: Multi-position\u003c\/li\u003e\n\u003cli\u003eIndoor Power Supply: 24V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eThrottle Type: EXV\u003c\/li\u003e\n\u003cli\u003eA2L Refrigerant Sensor: Included\u003c\/li\u003e\n\u003cli\u003eESP Range: 0–0.8 in. W.G.\u003c\/li\u003e\n\u003cli\u003eIndoor Dimensions (W x D x H): 21.61 x 21.50 x 27.80 in\u003c\/li\u003e\n\u003cli\u003eIndoor Dimensions (W x D x H): 549 x 546 x 706 mm\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions (W x D x H): 31.10 x 25.00 x 25.59 in\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions (W x D x H): 790 x 635 x 650 mm\u003c\/li\u003e\n\u003cli\u003eNet Weight: 96.78 lb (43.9 kg)\u003c\/li\u003e\n\u003cli\u003eGross Weight: 115.08 lb (52.2 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e4 Ton Configuration – CU-HM48BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Unit: CU-HM48BAHU\u003c\/li\u003e\n\u003cli\u003eRated Cooling Capacity: 45,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCooling Capacity Range: 16,000–48,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eRated Heating Capacity at 47°F: 48,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity Range at 47°F: 16,000–50,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 17°F: 34,400 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 5°F: 42,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eMaximum Heating Capacity at 5°F: 42,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCOP at 5°F: 1.85\u003c\/li\u003e\n\u003cli\u003eSEER2: 15.2\u003c\/li\u003e\n\u003cli\u003eEER2: 10.0\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region IV: 8.8\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region V: 7.4\u003c\/li\u003e\n\u003cli\u003eCOP: 3.12\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e60K Configuration – CU-HM55BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Unit: CU-HM55BAHU\u003c\/li\u003e\n\u003cli\u003eRated Cooling Capacity: 52,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCooling Capacity Range: 23,400–55,500 BTU\/h\u003c\/li\u003e\n\u003cli\u003eRated Heating Capacity at 47°F: 56,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity Range at 47°F: 11,700–61,300 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 17°F: 37,800 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 5°F: 45,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eMaximum Heating Capacity at 5°F: 45,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCOP at 5°F: 1.8\u003c\/li\u003e\n\u003cli\u003eMoisture Removal: 8.4 L\/h\u003c\/li\u003e\n\u003cli\u003eSEER2: 15.9\u003c\/li\u003e\n\u003cli\u003eEER2: 10.0\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region IV: 8.5\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region V: 6.9\u003c\/li\u003e\n\u003cli\u003eCOP: 2.8\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOutdoor Unit Specifications – CU-HM48BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCompressor Type: Rotary\u003c\/li\u003e\n\u003cli\u003eCompressor Model: MTH550UKPC8FU\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil: HAF68D1C\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil Charge: 1,800 mL\u003c\/li\u003e\n\u003cli\u003eMaximum Outdoor Airflow: 3,037.1 CFM\u003c\/li\u003e\n\u003cli\u003eOutdoor Noise Level: 65 dBA\u003c\/li\u003e\n\u003cli\u003eOutdoor Dimensions (W x D x H): 38.58 x 16.34 x 38.39 in\u003c\/li\u003e\n\u003cli\u003eOutdoor Dimensions (W x D x H): 980 x 415 x 975 mm\u003c\/li\u003e\n\u003cli\u003eOutdoor Net Weight: 201.06 lb (91.2 kg)\u003c\/li\u003e\n\u003cli\u003eOutdoor Gross Weight: 232.36 lb (105.4 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOutdoor Unit Specifications – CU-HM55BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCompressor Type: Twin-Rotary\u003c\/li\u003e\n\u003cli\u003eCompressor Model: ETPQ480D66UMU1\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil: VG75\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil Charge: 1,300 mL\u003c\/li\u003e\n\u003cli\u003eMaximum Outdoor Airflow: 2,649 CFM\u003c\/li\u003e\n\u003cli\u003eOutdoor Noise Level: 64 dBA\u003c\/li\u003e\n\u003cli\u003eOutdoor Dimensions (W x D x H): 37.48 x 16.34 x 52.48 in\u003c\/li\u003e\n\u003cli\u003eOutdoor Dimensions (W x D x H): 952 x 415 x 1,333 mm\u003c\/li\u003e\n\u003cli\u003eOutdoor Net Weight: 242.95 lb (110.2 kg)\u003c\/li\u003e\n\u003cli\u003eOutdoor Gross Weight: 275.13 lb (124.8 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications – CU-HM48BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Power Supply: 208\/230V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eOutdoor MCA: 38 A\u003c\/li\u003e\n\u003cli\u003eOutdoor MOP: 40 A\u003c\/li\u003e\n\u003cli\u003eCompressor RLA: 28 A\u003c\/li\u003e\n\u003cli\u003eOutdoor Fan Motor RLA: 2 A\u003c\/li\u003e\n\u003cli\u003eCommunication Wiring: AWG 20-2\u003c\/li\u003e\n\u003cli\u003eCooling System Power Input: 4,500 W rated (1,400–5,080 W)\u003c\/li\u003e\n\u003cli\u003eHeating System Power Input: 4,500 W rated (1,200–5,300 W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications – CU-HM55BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Power Supply: 208\/230V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eOutdoor MCA: 40 A\u003c\/li\u003e\n\u003cli\u003eOutdoor MOP: 40 A\u003c\/li\u003e\n\u003cli\u003eCompressor RLA: 31 A\u003c\/li\u003e\n\u003cli\u003eOutdoor Fan Motor RLA: 1.2 A\u003c\/li\u003e\n\u003cli\u003eCommunication Wiring: AWG 20-2\u003c\/li\u003e\n\u003cli\u003eCooling System Power Input: 5,200 W rated (1,870–6,000 W)\u003c\/li\u003e\n\u003cli\u003eHeating System Power Input: 5,861 W rated (1,090–6,270 W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eRefrigerant and Piping Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eLiquid Line Size: 3\/8 in (9.52 mm)\u003c\/li\u003e\n\u003cli\u003eGas Line Size: 3\/4 in (19 mm)\u003c\/li\u003e\n\u003cli\u003eConnection Method: Flared\u003c\/li\u003e\n\u003cli\u003eIndoor Throttle Type: EXV\u003c\/li\u003e\n\u003cli\u003eOutdoor Throttle Type: EXV\u003c\/li\u003e\n\u003cli\u003eMaximum Piping Length: 246 ft (75 m)\u003c\/li\u003e\n\u003cli\u003eMaximum Height Difference: 98 ft (30 m)\u003c\/li\u003e\n\u003cli\u003eMaximum Pre-Charged Length: 24.6 ft (7.5 m)\u003c\/li\u003e\n\u003cli\u003eAdditional Refrigerant Charge: 0.7 oz\/ft (65 g\/m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eRefrigerant Charge\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCU-HM48BAHU Factory Refrigerant Charge: 134.04 oz (3.8 kg)\u003c\/li\u003e\n\u003cli\u003eCU-HM55BAHU Factory Refrigerant Charge: 183.42 oz (5.2 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOperating Conditions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCooling Outdoor Operating Range: -22°F to 122°F (-30°C to 50°C)\u003c\/li\u003e\n\u003cli\u003eHeating Outdoor Operating Range: -22°F to 75°F (-30°C to 24°C)\u003c\/li\u003e\n\u003cli\u003eCold Climate Heating Operation: Down to -22°F (-30°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSystem Compatibility\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Unit: CS-HM60BAMU3\u003c\/li\u003e\n\u003cli\u003eCompatible Outdoor Unit: CU-HM48BAHU\u003c\/li\u003e\n\u003cli\u003eCompatible Outdoor Unit: CU-HM55BAHU\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eSystem Type: Panasonic INTERIOS Hybrid A-Coil Heat Pump\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Panasonic Products","offers":[{"title":"Default Title","offer_id":44875448418484,"sku":"kpi261-CS-HM60BAMU3","price":2057.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0645\/8484\/3444\/files\/CS-HM24BAAU1_ec9039a8-f10e-4fda-ba98-120cd5f2773c.png?v=1789910704"},{"product_id":"panasonic-cs-hm60baau4-interios-4-5-ton-a-coil-heat-pump","title":"Panasonic CS-HM60BAAU4 INTERIOS 4–5 Ton A-Coil Heat Pump","description":"\u003cp\u003eThe Panasonic INTERIOS CS-HM60BAAU4 is a multi-position cased A-coil designed for hybrid and dual-fuel heating and cooling applications. It integrates with a new or existing furnace to provide whole-home heating and cooling and is compatible with Panasonic CU-HM48BAHU and CU-HM55BAHU outdoor heat pump units. The system uses R454B refrigerant and includes an A2L refrigerant sensor for cold-climate applications.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e4–5 ton hybrid A-coil heat pump system\u003c\/li\u003e\n\u003cli\u003eCompatible with CU-HM48BAHU and CU-HM55BAHU outdoor units\u003c\/li\u003e\n\u003cli\u003eDesigned for hybrid and dual-fuel HVAC applications\u003c\/li\u003e\n\u003cli\u003eIntegrates with a new or existing furnace\u003c\/li\u003e\n\u003cli\u003eMulti-position installation design\u003c\/li\u003e\n\u003cli\u003eHorizontal and vertical installation capability\u003c\/li\u003e\n\u003cli\u003eR454B refrigerant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant sensor included\u003c\/li\u003e\n\u003cli\u003eCold-climate heating operation down to -22°F (-30°C)\u003c\/li\u003e\n\u003cli\u003eEXV electronic expansion valve\u003c\/li\u003e\n\u003cli\u003eEasy-maintenance design\u003c\/li\u003e\n\u003cli\u003eAluminum coil construction\u003c\/li\u003e\n\u003cli\u003eBuilt-in base pan for cold-climate operation\u003c\/li\u003e\n\u003cli\u003eCentral ducted whole-home heating and cooling\u003c\/li\u003e\n\u003cli\u003eSupports third-party 24V thermostat control\u003c\/li\u003e\n\u003cli\u003eOptional two-way communication wired controller with built-in Wi-Fi\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIndoor A-Coil Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Model: CS-HM60BAAU4\u003c\/li\u003e\n\u003cli\u003eProduct Type: Cased A-Coil Heat Pump\u003c\/li\u003e\n\u003cli\u003eApplication: Hybrid \/ Dual-Fuel Heating and Cooling\u003c\/li\u003e\n\u003cli\u003eSystem Capacity Class: 4–5 Ton\u003c\/li\u003e\n\u003cli\u003eInstallation: Multi-position\u003c\/li\u003e\n\u003cli\u003eIndoor Power Supply: 24V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eThrottle Type: EXV\u003c\/li\u003e\n\u003cli\u003eA2L Refrigerant Sensor: Included\u003c\/li\u003e\n\u003cli\u003eIndoor Airflow: Not specified in the official submittal\u003c\/li\u003e\n\u003cli\u003eIndoor Noise Level: Not specified in the official submittal\u003c\/li\u003e\n\u003cli\u003eExternal Static Pressure: Not specified in the official submittal\u003c\/li\u003e\n\u003cli\u003eIndoor Dimensions (W x D x H): 24-1\/2 x 21 x 28 in\u003c\/li\u003e\n\u003cli\u003eIndoor Dimensions (W x D x H): 622 x 533 x 711 mm\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions (W x D x H): 27-3\/4 x 26-1\/8 x 30-3\/8 in\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions (W x D x H): 705 x 665 x 770 mm\u003c\/li\u003e\n\u003cli\u003eNet Weight: 81 lb (36.8 kg)\u003c\/li\u003e\n\u003cli\u003eGross Weight: 92 lb (41.9 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e4 Ton Configuration – CU-HM48BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible Outdoor Unit: CU-HM48BAHU\u003c\/li\u003e\n\u003cli\u003eRated Cooling Capacity: 45,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCooling Capacity Range: 15,500–47,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCooling Input Power: 4,500 W rated (1,400–5,030 W)\u003c\/li\u003e\n\u003cli\u003eMoisture Removal: 6.7 L\/h\u003c\/li\u003e\n\u003cli\u003eRated Heating Capacity at 47°F: 50,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity Range at 47°F: 16,000–52,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 17°F: 34,400 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 5°F: 42,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eMaximum Heating Capacity at 5°F: 42,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Input Power: 4,650 W rated (1,200–5,300 W)\u003c\/li\u003e\n\u003cli\u003eCOP at 5°F: 1.85\u003c\/li\u003e\n\u003cli\u003eSEER2: 14.5\u003c\/li\u003e\n\u003cli\u003eEER2: 10.0\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region IV: 8.4\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region V: 7.3\u003c\/li\u003e\n\u003cli\u003eCOP: 3.15\u003c\/li\u003e\n\u003cli\u003eOutdoor Noise Level: 65 dBA\u003c\/li\u003e\n\u003cli\u003eOutdoor Airflow: 3,037 CFM\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e5 Ton Configuration – CU-HM55BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible Outdoor Unit: CU-HM55BAHU\u003c\/li\u003e\n\u003cli\u003eRated Cooling Capacity: 53,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCooling Capacity Range: 17,600–53,400 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCooling Input Power: 6,020 W rated (1,520–6,040 W)\u003c\/li\u003e\n\u003cli\u003eRated Heating Capacity at 47°F: 58,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity Range at 47°F: 21,200–59,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 17°F: 36,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 5°F: 43,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eMaximum Heating Capacity at 5°F: 43,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Input Power: 6,159 W rated (1,580–6,750 W)\u003c\/li\u003e\n\u003cli\u003eCOP at 5°F: 1.83\u003c\/li\u003e\n\u003cli\u003eSEER2: 14.5\u003c\/li\u003e\n\u003cli\u003eEER2: 8.8\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region IV: 8.1\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region V: 6.8\u003c\/li\u003e\n\u003cli\u003eCOP: 2.76\u003c\/li\u003e\n\u003cli\u003eOutdoor Noise Level: 64 dBA\u003c\/li\u003e\n\u003cli\u003eOutdoor Airflow: 2,649 CFM\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOutdoor Unit Specifications – CU-HM48BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Unit: CU-HM48BAHU\u003c\/li\u003e\n\u003cli\u003eCompressor Type: Rotary\u003c\/li\u003e\n\u003cli\u003eCompressor Model: MTH550UKPC8FU\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil: HAF68D1C\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil Charge: 1,800 mL\u003c\/li\u003e\n\u003cli\u003eOutdoor Airflow: 3,037 CFM\u003c\/li\u003e\n\u003cli\u003eOutdoor Noise Level: 65 dBA\u003c\/li\u003e\n\u003cli\u003eOutdoor Dimensions (W x D x H): 38-9\/16 x 16-3\/8 x 38-3\/8 in\u003c\/li\u003e\n\u003cli\u003eOutdoor Dimensions (W x D x H): 980 x 415 x 975 mm\u003c\/li\u003e\n\u003cli\u003eOutdoor Package Dimensions (W x D x H): 45-1\/16 x 19-11\/16 x 42-1\/2 in\u003c\/li\u003e\n\u003cli\u003eOutdoor Package Dimensions (W x D x H): 1,145 x 500 x 1,080 mm\u003c\/li\u003e\n\u003cli\u003eOutdoor Net Weight: 201 lb (91.2 kg)\u003c\/li\u003e\n\u003cli\u003eOutdoor Gross Weight: 232 lb (105.4 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOutdoor Unit Specifications – CU-HM55BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Unit: CU-HM55BAHU\u003c\/li\u003e\n\u003cli\u003eCompressor Type: Twin-Rotary\u003c\/li\u003e\n\u003cli\u003eCompressor Model: ETPQ480D66UMU1\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil: VG75\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil Charge: 1,300 mL\u003c\/li\u003e\n\u003cli\u003eOutdoor Airflow: 2,649 CFM\u003c\/li\u003e\n\u003cli\u003eOutdoor Noise Level: 64 dBA\u003c\/li\u003e\n\u003cli\u003eOutdoor Dimensions (W x D x H): 37-1\/2 x 16-3\/8 x 52-1\/2 in\u003c\/li\u003e\n\u003cli\u003eOutdoor Dimensions (W x D x H): 952 x 415 x 1,333 mm\u003c\/li\u003e\n\u003cli\u003eOutdoor Package Dimensions (W x D x H): 43-1\/8 x 19-1\/2 x 58-1\/4 in\u003c\/li\u003e\n\u003cli\u003eOutdoor Package Dimensions (W x D x H): 1,095 x 495 x 1,480 mm\u003c\/li\u003e\n\u003cli\u003eOutdoor Net Weight: 242 lb (110.2 kg)\u003c\/li\u003e\n\u003cli\u003eOutdoor Gross Weight: 275 lb (124.8 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications – CU-HM48BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Power Supply: 208\/230V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eOutdoor MCA: 38 A\u003c\/li\u003e\n\u003cli\u003eOutdoor MOP: 40 A\u003c\/li\u003e\n\u003cli\u003eCompressor RLA: 28 A\u003c\/li\u003e\n\u003cli\u003eOutdoor Fan Motor RLA: 2.0 A\u003c\/li\u003e\n\u003cli\u003eCommunication Wiring: AWG 20-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications – CU-HM55BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Power Supply: 208\/230V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eOutdoor MCA: 40 A\u003c\/li\u003e\n\u003cli\u003eOutdoor MOP: 40 A\u003c\/li\u003e\n\u003cli\u003eCompressor RLA: 31 A\u003c\/li\u003e\n\u003cli\u003eOutdoor Fan Motor RLA: 1.2 A\u003c\/li\u003e\n\u003cli\u003eCommunication Wiring: AWG 20-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eRefrigerant and Piping Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eLiquid Line Size: 3\/8 in (9.52 mm)\u003c\/li\u003e\n\u003cli\u003eGas Line Size: 3\/4 in (19 mm)\u003c\/li\u003e\n\u003cli\u003eConnection Method: Flared\u003c\/li\u003e\n\u003cli\u003eIndoor Throttle Type: EXV\u003c\/li\u003e\n\u003cli\u003eOutdoor Throttle Type: EXV\u003c\/li\u003e\n\u003cli\u003eMaximum Piping Length: 246 ft (75 m)\u003c\/li\u003e\n\u003cli\u003eMaximum Height Difference: 98 ft (30 m)\u003c\/li\u003e\n\u003cli\u003eMaximum Pre-Charged Length: 24.6 ft (7.5 m)\u003c\/li\u003e\n\u003cli\u003eAdditional Refrigerant Charge: 0.7 oz\/ft (65 g\/m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFactory Refrigerant Charge\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCU-HM48BAHU: 134.04 oz (3.8 kg)\u003c\/li\u003e\n\u003cli\u003eCU-HM55BAHU: 183.42 oz (5.2 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOperating Conditions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCooling Outdoor Operating Range: -22°F to 122°F (-30°C to 50°C)\u003c\/li\u003e\n\u003cli\u003eHeating Outdoor Operating Range: -22°F to 75°F (-30°C to 24°C)\u003c\/li\u003e\n\u003cli\u003eCold Climate Heating Operation: Down to -22°F (-30°C)\u003c\/li\u003e\n\u003cli\u003eIndoor Cooling Operating Range: 60°F to 90°F (16°C to 32°C)\u003c\/li\u003e\n\u003cli\u003eIndoor Heating Operating Range: 32°F to 86°F (0°C to 30°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eControl Options\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThird-party 24V thermostat compatible\u003c\/li\u003e\n\u003cli\u003eTwo-way communication wired controller with built-in Wi-Fi compatible\u003c\/li\u003e\n\u003cli\u003eDesigned for hybrid \/ dual-fuel system control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHybrid heating and cooling\u003c\/li\u003e\n\u003cli\u003eDual-fuel HVAC system\u003c\/li\u003e\n\u003cli\u003eCentral ducted whole-home heating and cooling\u003c\/li\u003e\n\u003cli\u003eIntegration with a new or existing furnace\u003c\/li\u003e\n\u003cli\u003eMulti-position A-coil installation\u003c\/li\u003e\n\u003cli\u003eCold-climate heat pump applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSystem Compatibility\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Unit: CS-HM60BAAU4\u003c\/li\u003e\n\u003cli\u003eCompatible Outdoor Unit: CU-HM48BAHU\u003c\/li\u003e\n\u003cli\u003eCompatible Outdoor Unit: CU-HM55BAHU\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eSystem Type: Panasonic INTERIOS Hybrid A-Coil Heat Pump\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Panasonic Products","offers":[{"title":"Default Title","offer_id":44875448451252,"sku":"kpi261-CS-HM60BAAU4","price":1995.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0645\/8484\/3444\/files\/CS-HM24BAAU1_cbe56053-94ef-46e6-ab9f-633de8616fe3.png?v=1789910704"}],"url":"https:\/\/kpaulsupply.com\/collections\/hybrid-heating-panasonic.oembed","provider":"KPaul Industrial","version":"1.0","type":"link"}