{"product_id":"panasonic-cs-hm60baau4-interios-4-5-ton-a-coil-heat-pump","title":"Panasonic CS-HM60BAAU4 INTERIOS 4–5 Ton A-Coil Heat Pump","description":"\u003cp\u003eThe Panasonic INTERIOS CS-HM60BAAU4 is a multi-position cased A-coil designed for hybrid and dual-fuel heating and cooling applications. It integrates with a new or existing furnace to provide whole-home heating and cooling and is compatible with Panasonic CU-HM48BAHU and CU-HM55BAHU outdoor heat pump units. The system uses R454B refrigerant and includes an A2L refrigerant sensor for cold-climate applications.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e4–5 ton hybrid A-coil heat pump system\u003c\/li\u003e\n\u003cli\u003eCompatible with CU-HM48BAHU and CU-HM55BAHU outdoor units\u003c\/li\u003e\n\u003cli\u003eDesigned for hybrid and dual-fuel HVAC applications\u003c\/li\u003e\n\u003cli\u003eIntegrates with a new or existing furnace\u003c\/li\u003e\n\u003cli\u003eMulti-position installation design\u003c\/li\u003e\n\u003cli\u003eHorizontal and vertical installation capability\u003c\/li\u003e\n\u003cli\u003eR454B refrigerant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant sensor included\u003c\/li\u003e\n\u003cli\u003eCold-climate heating operation down to -22°F (-30°C)\u003c\/li\u003e\n\u003cli\u003eEXV electronic expansion valve\u003c\/li\u003e\n\u003cli\u003eEasy-maintenance design\u003c\/li\u003e\n\u003cli\u003eAluminum coil construction\u003c\/li\u003e\n\u003cli\u003eBuilt-in base pan for cold-climate operation\u003c\/li\u003e\n\u003cli\u003eCentral ducted whole-home heating and cooling\u003c\/li\u003e\n\u003cli\u003eSupports third-party 24V thermostat control\u003c\/li\u003e\n\u003cli\u003eOptional two-way communication wired controller with built-in Wi-Fi\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIndoor A-Coil Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Model: CS-HM60BAAU4\u003c\/li\u003e\n\u003cli\u003eProduct Type: Cased A-Coil Heat Pump\u003c\/li\u003e\n\u003cli\u003eApplication: Hybrid \/ Dual-Fuel Heating and Cooling\u003c\/li\u003e\n\u003cli\u003eSystem Capacity Class: 4–5 Ton\u003c\/li\u003e\n\u003cli\u003eInstallation: Multi-position\u003c\/li\u003e\n\u003cli\u003eIndoor Power Supply: 24V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eThrottle Type: EXV\u003c\/li\u003e\n\u003cli\u003eA2L Refrigerant Sensor: Included\u003c\/li\u003e\n\u003cli\u003eIndoor Airflow: Not specified in the official submittal\u003c\/li\u003e\n\u003cli\u003eIndoor Noise Level: Not specified in the official submittal\u003c\/li\u003e\n\u003cli\u003eExternal Static Pressure: Not specified in the official submittal\u003c\/li\u003e\n\u003cli\u003eIndoor Dimensions (W x D x H): 24-1\/2 x 21 x 28 in\u003c\/li\u003e\n\u003cli\u003eIndoor Dimensions (W x D x H): 622 x 533 x 711 mm\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions (W x D x H): 27-3\/4 x 26-1\/8 x 30-3\/8 in\u003c\/li\u003e\n\u003cli\u003ePackage Dimensions (W x D x H): 705 x 665 x 770 mm\u003c\/li\u003e\n\u003cli\u003eNet Weight: 81 lb (36.8 kg)\u003c\/li\u003e\n\u003cli\u003eGross Weight: 92 lb (41.9 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e4 Ton Configuration – CU-HM48BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible Outdoor Unit: CU-HM48BAHU\u003c\/li\u003e\n\u003cli\u003eRated Cooling Capacity: 45,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCooling Capacity Range: 15,500–47,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCooling Input Power: 4,500 W rated (1,400–5,030 W)\u003c\/li\u003e\n\u003cli\u003eMoisture Removal: 6.7 L\/h\u003c\/li\u003e\n\u003cli\u003eRated Heating Capacity at 47°F: 50,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity Range at 47°F: 16,000–52,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 17°F: 34,400 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 5°F: 42,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eMaximum Heating Capacity at 5°F: 42,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Input Power: 4,650 W rated (1,200–5,300 W)\u003c\/li\u003e\n\u003cli\u003eCOP at 5°F: 1.85\u003c\/li\u003e\n\u003cli\u003eSEER2: 14.5\u003c\/li\u003e\n\u003cli\u003eEER2: 10.0\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region IV: 8.4\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region V: 7.3\u003c\/li\u003e\n\u003cli\u003eCOP: 3.15\u003c\/li\u003e\n\u003cli\u003eOutdoor Noise Level: 65 dBA\u003c\/li\u003e\n\u003cli\u003eOutdoor Airflow: 3,037 CFM\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e5 Ton Configuration – CU-HM55BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible Outdoor Unit: CU-HM55BAHU\u003c\/li\u003e\n\u003cli\u003eRated Cooling Capacity: 53,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCooling Capacity Range: 17,600–53,400 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCooling Input Power: 6,020 W rated (1,520–6,040 W)\u003c\/li\u003e\n\u003cli\u003eRated Heating Capacity at 47°F: 58,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity Range at 47°F: 21,200–59,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 17°F: 36,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Capacity at 5°F: 43,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eMaximum Heating Capacity at 5°F: 43,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating Input Power: 6,159 W rated (1,580–6,750 W)\u003c\/li\u003e\n\u003cli\u003eCOP at 5°F: 1.83\u003c\/li\u003e\n\u003cli\u003eSEER2: 14.5\u003c\/li\u003e\n\u003cli\u003eEER2: 8.8\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region IV: 8.1\u003c\/li\u003e\n\u003cli\u003eHSPF2 Region V: 6.8\u003c\/li\u003e\n\u003cli\u003eCOP: 2.76\u003c\/li\u003e\n\u003cli\u003eOutdoor Noise Level: 64 dBA\u003c\/li\u003e\n\u003cli\u003eOutdoor Airflow: 2,649 CFM\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOutdoor Unit Specifications – CU-HM48BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Unit: CU-HM48BAHU\u003c\/li\u003e\n\u003cli\u003eCompressor Type: Rotary\u003c\/li\u003e\n\u003cli\u003eCompressor Model: MTH550UKPC8FU\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil: HAF68D1C\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil Charge: 1,800 mL\u003c\/li\u003e\n\u003cli\u003eOutdoor Airflow: 3,037 CFM\u003c\/li\u003e\n\u003cli\u003eOutdoor Noise Level: 65 dBA\u003c\/li\u003e\n\u003cli\u003eOutdoor Dimensions (W x D x H): 38-9\/16 x 16-3\/8 x 38-3\/8 in\u003c\/li\u003e\n\u003cli\u003eOutdoor Dimensions (W x D x H): 980 x 415 x 975 mm\u003c\/li\u003e\n\u003cli\u003eOutdoor Package Dimensions (W x D x H): 45-1\/16 x 19-11\/16 x 42-1\/2 in\u003c\/li\u003e\n\u003cli\u003eOutdoor Package Dimensions (W x D x H): 1,145 x 500 x 1,080 mm\u003c\/li\u003e\n\u003cli\u003eOutdoor Net Weight: 201 lb (91.2 kg)\u003c\/li\u003e\n\u003cli\u003eOutdoor Gross Weight: 232 lb (105.4 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOutdoor Unit Specifications – CU-HM55BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Unit: CU-HM55BAHU\u003c\/li\u003e\n\u003cli\u003eCompressor Type: Twin-Rotary\u003c\/li\u003e\n\u003cli\u003eCompressor Model: ETPQ480D66UMU1\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil: VG75\u003c\/li\u003e\n\u003cli\u003eRefrigerant Oil Charge: 1,300 mL\u003c\/li\u003e\n\u003cli\u003eOutdoor Airflow: 2,649 CFM\u003c\/li\u003e\n\u003cli\u003eOutdoor Noise Level: 64 dBA\u003c\/li\u003e\n\u003cli\u003eOutdoor Dimensions (W x D x H): 37-1\/2 x 16-3\/8 x 52-1\/2 in\u003c\/li\u003e\n\u003cli\u003eOutdoor Dimensions (W x D x H): 952 x 415 x 1,333 mm\u003c\/li\u003e\n\u003cli\u003eOutdoor Package Dimensions (W x D x H): 43-1\/8 x 19-1\/2 x 58-1\/4 in\u003c\/li\u003e\n\u003cli\u003eOutdoor Package Dimensions (W x D x H): 1,095 x 495 x 1,480 mm\u003c\/li\u003e\n\u003cli\u003eOutdoor Net Weight: 242 lb (110.2 kg)\u003c\/li\u003e\n\u003cli\u003eOutdoor Gross Weight: 275 lb (124.8 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications – CU-HM48BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Power Supply: 208\/230V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eOutdoor MCA: 38 A\u003c\/li\u003e\n\u003cli\u003eOutdoor MOP: 40 A\u003c\/li\u003e\n\u003cli\u003eCompressor RLA: 28 A\u003c\/li\u003e\n\u003cli\u003eOutdoor Fan Motor RLA: 2.0 A\u003c\/li\u003e\n\u003cli\u003eCommunication Wiring: AWG 20-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eElectrical Specifications – CU-HM55BAHU\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor Power Supply: 208\/230V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003eOutdoor MCA: 40 A\u003c\/li\u003e\n\u003cli\u003eOutdoor MOP: 40 A\u003c\/li\u003e\n\u003cli\u003eCompressor RLA: 31 A\u003c\/li\u003e\n\u003cli\u003eOutdoor Fan Motor RLA: 1.2 A\u003c\/li\u003e\n\u003cli\u003eCommunication Wiring: AWG 20-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eRefrigerant and Piping Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eLiquid Line Size: 3\/8 in (9.52 mm)\u003c\/li\u003e\n\u003cli\u003eGas Line Size: 3\/4 in (19 mm)\u003c\/li\u003e\n\u003cli\u003eConnection Method: Flared\u003c\/li\u003e\n\u003cli\u003eIndoor Throttle Type: EXV\u003c\/li\u003e\n\u003cli\u003eOutdoor Throttle Type: EXV\u003c\/li\u003e\n\u003cli\u003eMaximum Piping Length: 246 ft (75 m)\u003c\/li\u003e\n\u003cli\u003eMaximum Height Difference: 98 ft (30 m)\u003c\/li\u003e\n\u003cli\u003eMaximum Pre-Charged Length: 24.6 ft (7.5 m)\u003c\/li\u003e\n\u003cli\u003eAdditional Refrigerant Charge: 0.7 oz\/ft (65 g\/m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFactory Refrigerant Charge\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCU-HM48BAHU: 134.04 oz (3.8 kg)\u003c\/li\u003e\n\u003cli\u003eCU-HM55BAHU: 183.42 oz (5.2 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOperating Conditions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCooling Outdoor Operating Range: -22°F to 122°F (-30°C to 50°C)\u003c\/li\u003e\n\u003cli\u003eHeating Outdoor Operating Range: -22°F to 75°F (-30°C to 24°C)\u003c\/li\u003e\n\u003cli\u003eCold Climate Heating Operation: Down to -22°F (-30°C)\u003c\/li\u003e\n\u003cli\u003eIndoor Cooling Operating Range: 60°F to 90°F (16°C to 32°C)\u003c\/li\u003e\n\u003cli\u003eIndoor Heating Operating Range: 32°F to 86°F (0°C to 30°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eControl Options\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThird-party 24V thermostat compatible\u003c\/li\u003e\n\u003cli\u003eTwo-way communication wired controller with built-in Wi-Fi compatible\u003c\/li\u003e\n\u003cli\u003eDesigned for hybrid \/ dual-fuel system control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHybrid heating and cooling\u003c\/li\u003e\n\u003cli\u003eDual-fuel HVAC system\u003c\/li\u003e\n\u003cli\u003eCentral ducted whole-home heating and cooling\u003c\/li\u003e\n\u003cli\u003eIntegration with a new or existing furnace\u003c\/li\u003e\n\u003cli\u003eMulti-position A-coil installation\u003c\/li\u003e\n\u003cli\u003eCold-climate heat pump applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSystem Compatibility\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Unit: CS-HM60BAAU4\u003c\/li\u003e\n\u003cli\u003eCompatible Outdoor Unit: CU-HM48BAHU\u003c\/li\u003e\n\u003cli\u003eCompatible Outdoor Unit: CU-HM55BAHU\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R454B\u003c\/li\u003e\n\u003cli\u003eSystem Type: Panasonic INTERIOS Hybrid A-Coil Heat Pump\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Panasonic Products","offers":[{"title":"Default Title","offer_id":44875448451252,"sku":"kpi261-CS-HM60BAAU4","price":1995.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0645\/8484\/3444\/files\/CS-HM24BAAU1_cbe56053-94ef-46e6-ab9f-633de8616fe3.png?v=1789910704","url":"https:\/\/kpaulsupply.com\/products\/panasonic-cs-hm60baau4-interios-4-5-ton-a-coil-heat-pump","provider":"KPaul Industrial","version":"1.0","type":"link"}