{"product_id":"panasonic-cs-ym9cd2uw-9-000-btu-low-profile-ducted-heat-pump","title":"Panasonic CS-YM9CD2UW 9,000 BTU Low-Profile Ducted Heat Pump","description":"\u003cp\u003eThe Panasonic CS-YM9CD2UW Project Series Low-Profile Ducted indoor unit is designed for concealed HVAC installations where ceiling space is limited. This compact 9,000 BTU ducted heat pump system provides efficient heating and cooling while maintaining a clean, unobtrusive appearance. It is suitable for retrofit, multi-family and light commercial applications and supports both horizontal and vertical installation.\u003c\/p\u003e\n\n\u003cp\u003eThe system pairs with the Panasonic CU-YM9CBUC inverter heat pump condenser and uses R454B refrigerant. With cold-climate heating operation down to -13°F (-25°C), ENERGY STAR Cold Climate certification, built-in condensate management and room freeze protection, the CS-YM9CD2UW is designed for year-round comfort in a variety of applications.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e9,000 BTU Cooling Capacity:\u003c\/strong\u003e Provides 9,000 BTU\/h of rated cooling capacity with an operating range of 3,100 to 11,900 BTU\/h.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10,000 BTU Heating Capacity:\u003c\/strong\u003e Provides 10,000 BTU\/h of rated heating capacity with a range of 3,600 to 14,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Profile Concealed Design:\u003c\/strong\u003e Compact indoor air handler is ideal for tight ceiling spaces and applications requiring a clean architectural appearance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontal \u0026amp; Vertical Installation:\u003c\/strong\u003e Designed to accommodate both horizontal and vertical installation configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Condensate Pump:\u003c\/strong\u003e Integrated condensate management simplifies installation in concealed ducted applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoom Freeze Protection:\u003c\/strong\u003e Protection activates at approximately 46°F (8°C) to help prevent excessively low room temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter Heat Pump Technology:\u003c\/strong\u003e Variable-capacity inverter operation provides efficient heating and cooling performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heating:\u003c\/strong\u003e Designed for heating operation down to -13°F (-25°C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR454B Refrigerant:\u003c\/strong\u003e Uses R454B refrigerant with zero ozone-depletion potential.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR Cold Climate Certified:\u003c\/strong\u003e Designed to meet ENERGY STAR cold-climate performance requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Controls Included:\u003c\/strong\u003e Wired and wireless remote control options are included for convenient operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Pan Heater:\u003c\/strong\u003e Included for improved outdoor-unit performance in cold-weather conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor Unit Model:\u003c\/strong\u003e CS-YM9CD2UW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit Model:\u003c\/strong\u003e CU-YM9CBUC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type:\u003c\/strong\u003e Low-Profile Ducted Inverter Heat Pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Capacity:\u003c\/strong\u003e 9,000 BTU\/h (3,100–11,900 BTU\/h)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Capacity:\u003c\/strong\u003e 2.64 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity:\u003c\/strong\u003e 10,000 BTU\/h (3,600–14,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity:\u003c\/strong\u003e 2.93 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Removal:\u003c\/strong\u003e 1.44 pints\/hour (0.68 L\/h)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Airflow:\u003c\/strong\u003e 324 CFM at Turbo\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatic Pressure Range:\u003c\/strong\u003e 0–0.4 in. w.g.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2:\u003c\/strong\u003e 19.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEER2:\u003c\/strong\u003e 12.8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSPF2 Region 4:\u003c\/strong\u003e 11.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSPF2 Region 5:\u003c\/strong\u003e 8.8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 208\/230V, Single Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Power Input:\u003c\/strong\u003e 703 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Power Input:\u003c\/strong\u003e 800 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R454B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heating Operation:\u003c\/strong\u003e Down to -13°F (-25°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIndoor Unit Dimensions \u0026amp; Weight\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 7-7\/8 x 27-9\/16 x 19-15\/16 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 200 x 700 x 506 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor Unit Weight:\u003c\/strong\u003e 39.5 lb (18 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOutdoor Unit Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit:\u003c\/strong\u003e CU-YM9CBUC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Dimensions (H x W x D):\u003c\/strong\u003e 21-7\/8 x 30-1\/8 x 11-7\/8 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Dimensions (H x W x D):\u003c\/strong\u003e 555 x 765 x 303 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit Weight:\u003c\/strong\u003e 62 lb (28 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Pan Heater:\u003c\/strong\u003e Included\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eResidential concealed ducted HVAC systems\u003c\/li\u003e\n\u003cli\u003eRetrofit installations\u003c\/li\u003e\n\u003cli\u003eMulti-family housing\u003c\/li\u003e\n\u003cli\u003eLight commercial applications\u003c\/li\u003e\n\u003cli\u003eApartments and compact spaces\u003c\/li\u003e\n\u003cli\u003eInstallations requiring concealed HVAC equipment\u003c\/li\u003e\n\u003cli\u003eApplications with limited ceiling space\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSystem Compatibility\u003c\/h2\u003e\n\u003cp\u003eThe CS-YM9CD2UW indoor unit is paired with the Panasonic CU-YM9CBUC outdoor inverter heat pump condenser. The CU-YM9CBUC is also used with other compatible Project Series indoor configurations, so system performance ratings should be referenced for the specific indoor\/outdoor combination.\u003c\/p\u003e","brand":"Panasonic Products","offers":[{"title":"Default Title","offer_id":44875448746164,"sku":"kpi261-CS-YM9CD2UW","price":1504.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0645\/8484\/3444\/files\/Slim_20Duct_Low_3b82be9b-6d93-4abb-b07e-966060430e36.png?v=1789910705","url":"https:\/\/kpaulsupply.com\/products\/panasonic-cs-ym9cd2uw-9-000-btu-low-profile-ducted-heat-pump","provider":"KPaul Industrial","version":"1.0","type":"link"}