{"product_id":"panasonic-cu-hm36bahu-interios-3-ton-outdoor-heat-pump","title":"Panasonic CU-HM36BAHU INTERIOS 3 Ton Outdoor Heat Pump","description":"\u003cp\u003eThe Panasonic INTERIOS CU-HM36BAHU is a 3-ton outdoor extreme heat pump designed for hybrid heating and cooling applications with compatible INTERIOS A-coil indoor units. It integrates with a new or existing furnace to provide whole-home heating and cooling while supporting cold-climate operation down to -22°F (-30°C). The system uses R454B refrigerant and is ENERGY STAR Cold Climate certified.\u003c\/p\u003e\n\n\u003cp\u003eThe CU-HM36BAHU delivers 36,000 BTU\/h of rated cooling capacity and 38,000 BTU\/h of rated heating capacity at 47°F. At 17°F, the rated heating capacity is 29,200 BTU\/h, while at 5°F the system provides 36,000 BTU\/h with a COP of 1.9. The outdoor unit uses a rotary compressor, electronic expansion valve, and supports flexible installation and hybrid dual-fuel operation.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e3-ton class outdoor heat pump for INTERIOS hybrid heating and cooling systems\u003c\/li\u003e\n\u003cli\u003e36,000 BTU\/h rated cooling capacity\u003c\/li\u003e\n\u003cli\u003e38,000 BTU\/h rated heating capacity at 47°F\u003c\/li\u003e\n\u003cli\u003e36,000 BTU\/h rated heating capacity at 5°F\u003c\/li\u003e\n\u003cli\u003e29,200 BTU\/h rated heating capacity at 17°F\u003c\/li\u003e\n\u003cli\u003eCold-climate operation down to -22°F (-30°C)\u003c\/li\u003e\n\u003cli\u003eR454B refrigerant with lower global warming potential than R410A\u003c\/li\u003e\n\u003cli\u003eENERGY STAR Cold Climate certified system\u003c\/li\u003e\n\u003cli\u003eRotary compressor with electronic expansion valve control\u003c\/li\u003e\n\u003cli\u003eBuilt-in A2L refrigerant sensor system\u003c\/li\u003e\n\u003cli\u003eBuilt-in base pan for extreme cold-weather heating operation\u003c\/li\u003e\n\u003cli\u003eDesigned for hybrid dual-fuel applications with compatible A-coil indoor units\u003c\/li\u003e\n\u003cli\u003eMaximum piping length up to 246 ft\u003c\/li\u003e\n\u003cli\u003eMaximum indoor-to-outdoor height difference of 98 ft\u003c\/li\u003e\n\u003cli\u003eOutdoor airflow up to 3,002 CFM\u003c\/li\u003e\n\u003cli\u003eOutdoor noise level of 64 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePerformance Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Unit:\u003c\/strong\u003e CU-HM36BAHU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Type:\u003c\/strong\u003e Hybrid A-Coil Heat Pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Capacity:\u003c\/strong\u003e 3 Ton\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Cooling Capacity:\u003c\/strong\u003e 36,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Capacity Range:\u003c\/strong\u003e 12,100–41,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Heating Capacity at 47°F:\u003c\/strong\u003e 38,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity Range at 47°F:\u003c\/strong\u003e 11,500–46,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Heating Capacity at 17°F:\u003c\/strong\u003e 29,200 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Heating Capacity at 5°F:\u003c\/strong\u003e 36,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Heating Capacity at 5°F:\u003c\/strong\u003e 36,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Removal:\u003c\/strong\u003e 4.91 L\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2:\u003c\/strong\u003e 15.8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEER2:\u003c\/strong\u003e 10.7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSPF2 Region IV:\u003c\/strong\u003e 9.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOP:\u003c\/strong\u003e 3.3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOP at 5°F:\u003c\/strong\u003e 1.9\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePower \u0026amp; Electrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Power Supply:\u003c\/strong\u003e 208\/230V, 1 Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor Power Supply:\u003c\/strong\u003e 24V, 1 Phase, 60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling System Power Input:\u003c\/strong\u003e 3,364 W rated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Power Input Range:\u003c\/strong\u003e 1,020–4,520 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating System Power Input:\u003c\/strong\u003e 3,375 W rated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Power Input Range:\u003c\/strong\u003e 800–4,540 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor MCA:\u003c\/strong\u003e 29 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor MOP:\u003c\/strong\u003e 30 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor RLA:\u003c\/strong\u003e 20.5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Fan Motor RLA:\u003c\/strong\u003e 2.4 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Wiring:\u003c\/strong\u003e AWG 20-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompressor \u0026amp; Refrigeration\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Type:\u003c\/strong\u003e Rotary\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Model:\u003c\/strong\u003e EKPQ420D1UMUA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R454B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Refrigerant Charge:\u003c\/strong\u003e 126.99 oz \/ 3.6 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Refrigerant:\u003c\/strong\u003e 0.7 oz\/ft \/ 65 g\/m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant Oil:\u003c\/strong\u003e VG75\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant Oil Charge:\u003c\/strong\u003e 1,460 mL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThrottle Type:\u003c\/strong\u003e Electronic Expansion Valve (EXV)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePiping Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Method:\u003c\/strong\u003e Flared\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid Pipe Size:\u003c\/strong\u003e 3\/8 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Pipe Size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Piping Length:\u003c\/strong\u003e 246 ft \/ 75 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Height Difference:\u003c\/strong\u003e 98 ft \/ 30 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Pre-Charged Piping Length:\u003c\/strong\u003e 24.6 ft \/ 7.5 m\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOperating Conditions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Operating Range:\u003c\/strong\u003e -22°F to 122°F (-30°C to 50°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Operating Range:\u003c\/strong\u003e -22°F to 75°F (-30°C to 24°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Climate Heating Operation:\u003c\/strong\u003e Down to -22°F (-30°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eOutdoor Unit Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W × D × H):\u003c\/strong\u003e 38.58 × 16.34 × 38.39 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W × D × H):\u003c\/strong\u003e 980 × 415 × 975 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 204.15 lb \/ 92.6 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGross Weight:\u003c\/strong\u003e 235.23 lb \/ 106.7 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Outdoor Airflow:\u003c\/strong\u003e 3,002 CFM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Noise Level:\u003c\/strong\u003e 64 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompatible Indoor Units\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCS-HM36BAAU1\u003c\/li\u003e\n\u003cli\u003eCS-HM36BAAU2\u003c\/li\u003e\n\u003cli\u003eCS-HM36BAAU3\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cp\u003eThe CU-HM36BAHU is designed for central ducted hybrid heating and cooling systems. When paired with a compatible INTERIOS A-coil, it can integrate with a furnace to provide dual-fuel whole-home heating and cooling. The system supports multi-position A-coil installation, R454B refrigerant, A2L refrigerant sensing, and extreme cold-climate operation.\u003c\/p\u003e","brand":"Panasonic Products","offers":[{"title":"Default Title","offer_id":44875447533748,"sku":"kpi261-CU-HM36BAHU","price":6451.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0645\/8484\/3444\/files\/CS-HM36BAAU2.png?v=1789910704","url":"https:\/\/kpaulsupply.com\/products\/panasonic-cu-hm36bahu-interios-3-ton-outdoor-heat-pump","provider":"KPaul Industrial","version":"1.0","type":"link"}