{"product_id":"sos-cleanroom-texwipe-stx7114m-sterile-mini-alphamop-microdenier-replacement-mop-covers-refills-case-qty-case","title":"SOS Cleanroom Texwipe STX7114M Sterile Mini AlphaMop Microdenier Replacement Mop Covers (Refills) (Case Qty.) - Case","description":"\u003cdiv style=\"border: 2px solid #0b5aa2; border-radius: 8px; padding: 18px; font-family: inherit; font-size: inherit; line-height: 1.45;\"\u003e\n\u003cdiv style=\"margin: 0 0 10px 0;\"\u003e\n\u003cdiv style=\"font-weight: bold; font-size: 20px; margin: 0 0 6px 0;\"\u003e\u003cspan style=\"font-size: 18pt;\"\u003eTexwipe STX7114M Mini AlphaMop™ \/ Isolator Cleaning Tool™ Sterile Microdenier Replacement Mop Covers (Refills)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin: 0;\"\u003eSTX7114M is a sterile, microdenier (microfiber) replacement cover set designed for the Mini AlphaMop™ \/ Isolator Cleaning Tool™ platform used in isolators, glove boxes, biosafety cabinets, laminar flow hoods, and other small, hard-to-reach critical zones. The microdenier knit is engineered to lift and hold fine contamination while supporting streak-free cleaning and strong sorption for common cleanroom disinfectants (including quat systems) when used with validated wipe\/mop chemistry and technique. \u003cbr\u003e\u003cbr\u003eFor over 35 years, SOS and Texwipe have been close partners, and SOSCleanroom is the authorized Master Distributor of ITW Texwipe for the United States market. That relationship matters when you are standardizing cleanroom mopping systems: it supports continuity of supply, stable product lineage, and fast access to the manufacturer documentation your QA\/QC team expects.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr style=\"border: 0; border-top: 1px solid #0b5aa2; margin: 12px 0;\"\u003e\n\u003cdiv style=\"font-weight: bold; font-size: 18px; margin: 0 0 8px 0;\"\u003ePublished configuration (STX7114M)\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 12px 18px; padding: 0;\"\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Dry mop covers (replacement covers \/ refills)\u003c\/li\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003eSterile:\u003c\/strong\u003e Yes (pre-sterilized \/ gamma irradiated; see documentation)\u003c\/li\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Microdenier (microfiber) cover fabric (polyester microdenier construction as published)\u003c\/li\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003eIntended platform:\u003c\/strong\u003e Mini AlphaMop™ \/ Isolator Cleaning Tool™ system (small-area critical cleaning tool)\u003c\/li\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003eApplications (as published):\u003c\/strong\u003e Isolators; small, hard-to-reach areas; glove boxes; biosafety cabinets; laminar flow hoods; workbenches\u003c\/li\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003eCleanroom environment (as published):\u003c\/strong\u003e ISO Class 3–7 (Class 1–100,000); EU Grade A–D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background: #eaf3ff; border: 1px solid #0b5aa2; border-radius: 8px; padding: 12px; margin: 12px 0;\"\u003e\n\u003cdiv style=\"font-weight: bold; margin: 0 0 6px 0;\"\u003eLow-linting performance — and the reality check\u003c\/div\u003e\n\u003cdiv style=\"margin: 0;\"\u003eThese covers are engineered for low-linting, low-residue cleaning in controlled environments. Even so, no textile or mop system is truly “lint-free.” Treat mop covers as contamination-controlled components: control how they are introduced, how they are staged, and what touches the working face before and during use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr style=\"border: 0; border-top: 1px solid #0b5aa2; margin: 12px 0;\"\u003e\n\u003cdiv style=\"font-weight: bold; font-size: 18px; margin: 0 0 8px 0;\"\u003ePackaging and sterile transfer notes\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 10px 0;\"\u003eUse the packout information below to align purchasing, gowning-room staging, and aseptic transfer SOPs. When counts differ by listing vs. manufacturer documentation, qualify against the documents shipped with the case (COA\/processing\/irradiation certificate) and your site inventory controls.\u003c\/div\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 12px 0;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; min-width: 640px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border-bottom: 2px solid #0b5aa2; padding: 8px 6px;\"\u003ePackout element\u003c\/th\u003e\n\u003cth style=\"text-align: left; border-bottom: 2px solid #0b5aa2; padding: 8px 6px;\"\u003ePublished value\u003c\/th\u003e\n\u003cth style=\"text-align: left; border-bottom: 2px solid #0b5aa2; padding: 8px 6px;\"\u003eWhy it matters in critical environments\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003eInner bag content\u003c\/td\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003e5 covers and 1 pad per bag (manufacturer)\u003c\/td\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003eSupports controlled dispensing and reduced “bag dwell time” at the hood\/isolator interface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003eBags per case\u003c\/td\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003e25 bags per case (manufacturer)\u003c\/td\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003eEnables lot-controlled issuance by shift, room, or suite for deviation traceability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003eTotal per case\u003c\/td\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003eManufacturer documentation: 125 covers and 25 pads per case (25 bags of 5 covers and 1 pad).\u003cbr\u003eSOSCleanroom site listing: 120 covers and 12 pads per case (12 bags of 10 covers and 1 pad).\u003c\/td\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003eCounts impact cycle counts, reorder points, and batch record reconciliation. Confirm your site’s qualified packout at receiving.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003eSterile presentation\u003c\/td\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003eSterile product with sterile validation documentation available upon request (manufacturer)\u003c\/td\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003eDrives how you introduce materials into ISO 5\/Grade A zones and how you document sterile status in GMP records.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr style=\"border: 0; border-top: 1px solid #0b5aa2; margin: 12px 0;\"\u003e\n\u003cdiv style=\"font-weight: bold; font-size: 18px; margin: 0 0 8px 0;\"\u003ePractical cleanroom use guidance (technicians and engineers)\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 12px 18px; padding: 0;\"\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003eStart clean, stay clean:\u003c\/strong\u003e Introduce unopened bags using your approved transfer method (pass-through, spray\/wipe, or bag-in-bag-out). Do not stage open bags in uncontrolled air.\u003c\/li\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003eOne cover per defined task:\u003c\/strong\u003e Use a fresh cover whenever you change rooms, change chemistry, or transition from “dirty perimeter” to “critical interior” zones. Microdenier holds contamination effectively—do not push beyond SOP limits.\u003c\/li\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003eContact discipline:\u003c\/strong\u003e Maintain full-face contact without excessive pressure. High pressure can drive residues into microtexture, increase smearing, and create uneven wet films.\u003c\/li\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003eEdge control:\u003c\/strong\u003e Use overlapping strokes and keep the leading edge oriented consistently. Random direction changes are a common cause of redeposition lines.\u003c\/li\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003ePad usage:\u003c\/strong\u003e Pads are designed to maintain uniform contact. Replace pads when compressed, torn, or chemically compromised (per SOP) to avoid skip marks and incomplete wetting.\u003c\/li\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003eGlove control:\u003c\/strong\u003e Avoid touching the working face of the cover. If you contact the face, treat it as contaminated and change the cover to protect the process.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr style=\"border: 0; border-top: 1px solid #0b5aa2; margin: 12px 0;\"\u003e\n\u003cdiv style=\"font-weight: bold; font-size: 18px; margin: 0 0 8px 0;\"\u003eCompatibility and chemistry notes (as published)\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 12px 18px; padding: 0;\"\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003eDisinfectant compatibility:\u003c\/strong\u003e Microdenier covers are published as compatible with all disinfectants, including quat-based systems (manufacturer guidance). Always verify your specific formulation under your site’s validation protocol.\u003c\/li\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003eSolvent use:\u003c\/strong\u003e When solvents are used in critical areas, apply with controlled wetting—avoid oversaturation that can cause dripping, pooling, and streaks. Follow your chemical exposure, VOC, and residue limits.\u003c\/li\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003eResidue management:\u003c\/strong\u003e If a disinfectant leaves film, use your approved neutralizer\/rinse step (if applicable) and change covers between chemical steps to prevent cross-chemistry reactions and residue carryover.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background: #eaf3ff; border: 1px solid #0b5aa2; border-radius: 8px; padding: 12px; margin: 12px 0;\"\u003e\n\u003cdiv style=\"font-weight: bold; margin: 0 0 6px 0;\"\u003eCritical-environment reminder\u003c\/div\u003e\n\u003cdiv style=\"margin: 0;\"\u003eIn ISO\/GMP spaces, the mop cover is part of the contamination-control system—not general housekeeping. Pair STX7114M with validated chemistry, defined stroke patterns, dwell-time discipline, and documented change-out rules to reduce the risk of redeposition, residue, and bioburden persistence.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr style=\"border: 0; border-top: 1px solid #0b5aa2; margin: 12px 0;\"\u003e\n\u003cdiv style=\"font-weight: bold; font-size: 18px; margin: 0 0 8px 0;\"\u003eSterility, validation, and shelf-life notes (as published)\u003c\/div\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 12px 0;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; min-width: 640px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border-bottom: 2px solid #0b5aa2; padding: 8px 6px;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"text-align: left; border-bottom: 2px solid #0b5aa2; padding: 8px 6px;\"\u003ePublished detail\u003c\/th\u003e\n\u003cth style=\"text-align: left; border-bottom: 2px solid #0b5aa2; padding: 8px 6px;\"\u003eImplementation tip\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003eSterilization\u003c\/td\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003eGamma irradiated to a Sterility Assurance Level (SAL) of 10\u003csup\u003e?6\u003c\/sup\u003e (manufacturer)\u003c\/td\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003eStore and issue by lot; retain irradiation\/processing documentation per GMP record-retention rules.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003eCertificates\u003c\/td\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003eCertificates of Compliance, Analysis, and Processing\/Irradiation available (manufacturer)\u003c\/td\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003eFor investigations, reconcile lot numbers across the case label, certificates, and batch documentation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003eShelf life\u003c\/td\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003eSterile: 3 years from date of manufacture (manufacturer)\u003c\/td\u003e\n\u003ctd style=\"border-bottom: 1px solid #d6e4f5; padding: 8px 6px;\"\u003eImplement FEFO (first-expire, first-out) and quarantine any compromised packaging.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr style=\"border: 0; border-top: 1px solid #0b5aa2; margin: 12px 0;\"\u003e\n\u003cdiv style=\"font-weight: bold; font-size: 18px; margin: 0 0 8px 0;\"\u003eCommon failure modes\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 12px 18px; padding: 0;\"\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003eStreaking \/ smearing:\u003c\/strong\u003e Usually from over-wetting, poor dwell control, or reusing a cover past its loading limit. Prevent with measured wetting, defined strokes, and change-out discipline.\u003c\/li\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003eRedeposition lines:\u003c\/strong\u003e Typically caused by “turning back into the clean zone” with a loaded leading edge. Prevent by maintaining a clean-to-dirty workflow and overlapping strokes.\u003c\/li\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003eResidue carryover:\u003c\/strong\u003e Occurs when changing chemistries without a cover change, or when the cover contacts contaminated staging areas. Prevent by segregating chemical steps and staging in controlled packaging.\u003c\/li\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003eFiber\/particle mobilization:\u003c\/strong\u003e Triggered by aggressive scrubbing on abrasive surfaces or damaged pad\/cover interfaces. Prevent by inspecting pads, controlling pressure, and replacing damaged components immediately.\u003c\/li\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003e\n\u003cstrong\u003ePackaging compromise:\u003c\/strong\u003e Tears, seal failures, or wet-out can invalidate sterile introduction assumptions. Prevent with receiving inspection and controlled storage; quarantine suspect cases.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr style=\"border: 0; border-top: 1px solid #0b5aa2; margin: 12px 0;\"\u003e\n\u003cdiv style=\"font-weight: bold; font-size: 18px; margin: 0 0 8px 0;\"\u003eStorage and handling best practices\u003c\/div\u003e\n\u003cul style=\"margin: 0 0 12px 18px; padding: 0;\"\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003eKeep unopened bags in original case packaging until issuance to reduce handling and label damage.\u003c\/li\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003eStore in a clean, dry area away from direct sunlight and chemical vapors that can degrade packaging over time.\u003c\/li\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003eUse lot-controlled issuance (room\/suite\/shift) to support deviation investigations and traceability.\u003c\/li\u003e\n\u003cli style=\"margin: 0 0 6px 0;\"\u003eDo not stage opened covers near floor drains, trash, or non-controlled carts where airborne transport risk is highest.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background: #f3f3f3; border-radius: 8px; padding: 12px; margin: 12px 0;\"\u003e\n\u003cdiv style=\"font-weight: bold; margin: 0 0 6px 0;\"\u003eDocumentation \u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 6px 0;\"\u003eSOS-hosted Texwipe datasheet (STX7114M): \u003ca href=\"https:\/\/www.soscleanroom.com\/content\/texwipe_pdf\/STX7114M.pdf\" target=\"_blank\" rel=\"noopener\"\u003eClick Here\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0;\"\u003eTexwipe manufacturer TDS (Mini AlphaMop™ Series, US-TDS-068 Rev.11\/21): \u003ca href=\"https:\/\/www.texwipe.com\/images\/uploaded\/documents\/Mops\/Texwipe-Mini-AlphaMop-TDS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eClick Here\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 10px 0 0 0; font-size: 12px;\"\u003e\n\u003cdiv style=\"margin: 0 0 6px 0;\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003eIf you have any questions please email us at Sales@SOSsupply.com or give us a call at (214)340-8574.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin: 0;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cbr\u003eCheck out the AI ChatBot powered by SOSCleanroom data libraries - give it a try!\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin: 0;\"\u003e \u003c\/div\u003e\n\u003cdiv style=\"margin: 0;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 12pt;\"\u003eTHIS IS NEW FOR 2026!\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 10px 0 0 0; font-size: 12px;\"\u003e\u003cem\u003e© 2026 SOS Supply. All rights reserved.\u003c\/em\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Specialty Optical Systems \/ SOS Cleanroom","offers":[{"title":"Default Title","offer_id":44378668499124,"sku":"kpi259-STX7114M CASE","price":657.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0645\/8484\/3444\/files\/1871__08176.1491490244.png?v=1788682196","url":"https:\/\/kpaulsupply.com\/products\/sos-cleanroom-texwipe-stx7114m-sterile-mini-alphamop-microdenier-replacement-mop-covers-refills-case-qty-case","provider":"KPaul Industrial","version":"1.0","type":"link"}