Controls
The Ranco Heat Pump Controls provide accurate control of temperature and defrost for heat pumps. The E15-2601 provides field-adjustable timer control for de-icing of heat pump outdoor coils. Interlock prevents more than one defrost cycle per time period and temperature must be 28°F or lower to start.
Features and Benefits:
- Laser-welded stainless steel sensing elements
- Narrower differentials attainable
- Defrost includes field selectable defrost cycles
Additional Information
Additional Information
Series ApplicationE15 Series Timer-Initiated Heat Pump De-Ice Control
ApplicationHeat Pump Controls
Electrical Rating240V
SwitchSPDT
Temperature RangeAdjustable 55°F to 78°F
Capillary Length60"
TimingField Selectable: 30, 45, or 90 Minutes
Sensing Element5/16" x 5-1/16" Bulb