- 30-day returns
- Fast shipping
- Secure payments
- Over 300,000 products
category:
Refrigeration
country_of_origin:
US
manufacturer:
Robertshaw
mpn:
B877-00
subcategory:
Defrost Timers
Program Modules: Defrost initiation is adjustable from 1-12 operations per circuit, per day; minimum 2 hours required between successive operations. Mechanical defrost termination is adjustable from 6-106 minutes in one-minute increments. Solenoid termination is optional. Instantaneous transfer if solenoid is energized at time of defrost initiation. Two SPDT snap switches per module. 3/16" male push-on switch terminals. Switch rating: 10 Amps, 1/3 HP, 120-240V AC; 345 VA pilot duty.
Features and Benefits
Features and Benefits:
- Extra trippers, part number X-7248 (12 per bag). Recognized under the component program of UL and CSA
- Ru Listed and CSA Approved
Additional Information
Additional Information
Series ApplicationRM Series Program Module
Electrical Rating120V AC, 60 Hz
CommentsWith solenoid
Agency ApprovalsUL Recognized|CSA
High Pressure (Open High) Cut-Out1 (0.5)
CircuitCircuit Mod.
HourEven Half Hour