Ansell BioClean™ CGL Clean Nitrile RABS/Isolator Gloves — Class 10 / ISO 4, 33" Barrier Protection for VHP, IPA and Critical Disinfectant Workflows
Class 10 / ISO 4 Nitrile RABS / isolator glove Ambidextrous 33" / 840 mm length 100% water leak tested ASTM D6978 tested Port sizes: 8" or 12" Non-sterile 20 gloves / case
Product overview
Ansell BioClean™ CGL Clean Nitrile RABS/Isolator Gloves are long-length, cleanroom-processed nitrile gloves designed to provide a robust barrier between the operator and the process in Class 10 / ISO 4 critical environments. They are commonly selected for restricted access barrier systems (RABS) and isolators where glove integrity, repeatable decontamination routines and documentation discipline matter. CGL gloves are described as resistant to vaporized hydrogen peroxide (VHP), isopropyl alcohol (IPA) and common disinfectants, and they are 100% water leak tested to support product protection and personal protection in high-consequence workcells.
Why customers choose BioClean™ CGL
- Designed for RABS/isolator use where the glove is a primary product-contact and contamination control interface in ISO 4 operations.
- 100% water leak tested to support confidence in glove integrity during long campaigns, interventions and investigations.
- Resistance described for VHP, IPA and common disinfectants to align with typical isolator decontamination and wipe-down workflows.
- ASTM D6978 testing is commonly referenced when customers need gloves evaluated for chemotherapy drug handling workflows (note: manufacturer notes this is not listed in the U.S. FDA 510(k)).
- Long, 33" (840 mm) design supports extended reach and reduces the need for risky repositioning inside barrier systems.
Recommended applications
- Aseptic processing support tasks performed through isolator ports and RABS gauntlets
- Filling/finishing interventions where glove integrity is treated as a critical control
- Decontamination-compatible workflows involving VHP cycles and routine IPA wipe-down steps (as defined by your CCS/SOP)
- Handling of cytotoxic/chemotherapy drugs where ASTM D6978 evaluation is part of the risk assessment
- Critical electronics and life-sciences barrier workcells where low particulate contribution and repeatable processing are required
Note: These gloves are non-sterile. In sterile manufacturing, sterility needs are process-defined. Many programs rely on validated decontamination of the isolator/RABS system and glove surfaces per documented procedures. Always align glove selection, port fit, integrity testing, and change-out frequency to your CCS/SOP and risk assessment.